PURPOSE: This study investigated the response of the ventilatory threshold (VT) to acute normobaric hypoxia and compared the agreement between software-based algorithms which use automatic detection to identify the VT. Results were used to examine whether the VT can be used as a physiological parameter to prescribe and monitor exercise intensity in hypoxic exercise training programs. METHODS: Fourteen untrained individuals (7 women, 7 men; age 22 ± 2 years, [Formula: see text]O2peak 46 ± 7 mL kg(-1) min(-1)) completed five identical graded exercise tests (randomized order) on a cycle ergometer to measure VT at sea-level (SL) and in response to four normobaric hypoxic conditions (FIO2: 0.185, 0.165, 0.142, 0.125) equivalent to 1,000, 2,000, 3,000 and 4,000 m. Data were analyzed using a one-way analysis of variance (ANOVA) with repeated measures. RESULTS: The VT was similar across all conditions (SL = 1.98 ± 0.46, 1,000 m = 2.03 ± 0.61, 2,000 m = 2.27 ± 0.62, 3,000 m = 1.84 ± 0.50, 4,000 m = 2.29 ± 0.58 L min(-1)) for all algorithms used despite a reduction in arterial oxygen saturation at 3,000 (P ≤ 0.01) and 4,000 m (P ≤ 0.01) compared with SL values. CONCLUSION: The VT appears to be a suitable physiological parameter for exercise prescription in normobaric hypoxia up to an altitude of 4,000 m.
PURPOSE: This study investigated the response of the ventilatory threshold (VT) to acute normobaric hypoxia and compared the agreement between software-based algorithms which use automatic detection to identify the VT. Results were used to examine whether the VT can be used as a physiological parameter to prescribe and monitor exercise intensity in hypoxic exercise training programs. METHODS: Fourteen untrained individuals (7 women, 7 men; age 22 ± 2 years, [Formula: see text]O2peak 46 ± 7 mL kg(-1) min(-1)) completed five identical graded exercise tests (randomized order) on a cycle ergometer to measure VT at sea-level (SL) and in response to four normobaric hypoxic conditions (FIO2: 0.185, 0.165, 0.142, 0.125) equivalent to 1,000, 2,000, 3,000 and 4,000 m. Data were analyzed using a one-way analysis of variance (ANOVA) with repeated measures. RESULTS: The VT was similar across all conditions (SL = 1.98 ± 0.46, 1,000 m = 2.03 ± 0.61, 2,000 m = 2.27 ± 0.62, 3,000 m = 1.84 ± 0.50, 4,000 m = 2.29 ± 0.58 L min(-1)) for all algorithms used despite a reduction in arterial oxygen saturation at 3,000 (P ≤ 0.01) and 4,000 m (P ≤ 0.01) compared with SL values. CONCLUSION: The VT appears to be a suitable physiological parameter for exercise prescription in normobaric hypoxia up to an altitude of 4,000 m.
Authors: Morten Overgaard; Peter Rasmussen; Aske M Bohm; Thomas Seifert; Patrice Brassard; Morten Zaar; Pernille Homann; Kevin A Evans; Henning B Nielsen; Niels H Secher Journal: FASEB J Date: 2012-03-21 Impact factor: 5.191
Authors: Michael Ofner; Manfred Wonisch; Mario Frei; Gerhard Tschakert; Wolfgang Domej; Julia M Kröpfl; Peter Hofmann Journal: J Sports Sci Med Date: 2014-12-01 Impact factor: 2.988