Literature DB >> 24756674

Fluoride removal from aqueous solution by direct contact membrane distillation: theoretical and experimental studies.

Ali Boubakri1, Raja Bouchrit, Amor Hafiane, Salah Al-Tahar Bouguecha.   

Abstract

Direct contact membrane distillation (DCMD) process using polyvinylidene fluoride (PVDF) membrane was used for fluoride removal from aqueous solution. This study has been carried out on heat and mass transfer analyses in DCMD. The dusty-gas model was used to analyze the mass transfer mechanism and to calculate the permeate flux. The heat transfer is analyzed based on energy balance, and the different layers are considered as a series of thermal resistances. Mass transfer analysis showed that the transition Knudsen-molecular diffusion is the dominant mechanism to describe the transport of water vapor through the pores of the PVDF membrane. The most significant operating parameter is the feed temperature. The permeate increases sensitively with feed temperature and velocity, and it shows insignificant change with feed salts concentration. Heat transfer analysis showed the conduction through the matrix of the membrane presents the major part of available energy. The increasing feed temperature leads to increase thermal efficiency (TE) and decrease temperature polarization coefficient (TPC). The experimental results are in good agreement with theoretical values. Therefore, it is suggested to work at high feed temperature, which will benefit both the thermal efficiency and permeate flux. The experimental results proved that DCMD process is able to produce almost fluoride-free water suitable for many beneficial uses.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24756674     DOI: 10.1007/s11356-014-2858-z

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  5 in total

1.  Removal of fluoride ions from aqueous solution by waste mud.

Authors:  Baris Kemer; Duygu Ozdes; Ali Gundogdu; Volkan N Bulut; Celal Duran; Mustafa Soylak
Journal:  J Hazard Mater       Date:  2009-03-03       Impact factor: 10.588

2.  Removal of arsenic from contaminated groundwater by solar-driven membrane distillation using three different commercial membranes.

Authors:  Parimal Pal; Ajay K Manna
Journal:  Water Res       Date:  2010-06-01       Impact factor: 11.236

3.  Treatment of radioactive wastewater using direct contact membrane distillation.

Authors:  Haiyang Liu; Jianlong Wang
Journal:  J Hazard Mater       Date:  2013-07-27       Impact factor: 10.588

Review 4.  Review of fluoride removal from drinking water.

Authors:  M Mohapatra; S Anand; B K Mishra; Dion E Giles; P Singh
Journal:  J Environ Manage       Date:  2009-09-22       Impact factor: 6.789

5.  Multi-criteria assessment of community-based fluoride-removal technologies for rural Ethiopia.

Authors:  Lars Osterwalder; C Annette Johnson; Hong Yang; Richard B Johnston
Journal:  Sci Total Environ       Date:  2013-11-14       Impact factor: 7.963

  5 in total
  2 in total

1.  Micro-bubbles enhanced breakage warning for hollow fiber membrane integrity with a low-cost real-time monitoring device.

Authors:  Jie Wang; Changchun Xin; Jinzhao Li; Lianfa Song; Hui Jia
Journal:  Environ Sci Pollut Res Int       Date:  2018-06-18       Impact factor: 4.223

2.  A triangular fuzzy TOPSIS-based approach for the application of water technologies in different emergency water supply scenarios.

Authors:  Jianhua Qu; Xianlin Meng; Huan Yu; Hong You
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-25       Impact factor: 4.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.