Literature DB >> 24756534

ACL reconstruction using bone-patella tendon-bone autograft: press-fit technique vs. interference screw fixation.

M M Sarzaeem1, F Najafi, M Razi, M A Najafi.   

Abstract

PURPOSE: The gold standard in ACL reconstructions has been the bone-patellar tendon-bone autograft fixed with interference screws. This prospective, randomized clinical trial aimed to compare two methods of fixation for BPTB grafts: press-fit fixation vs. interference screw, over a 12-month follow-up interval.
METHODS: 158 patients with an average age of 29.8 years, between 2011 and 2012, were treated for torn ACL. 82 patients underwent reconstruction with BPTB autograft with a press fit fixation technique, and in 76 cases an interference screw was used. At the time of final follow-up, 71 patients in press-fit group and 65 patients in interference screw group were evaluated in terms of return to pre-injury activity level, pain, knee stability, range of motion, IKDC score and complications.
RESULTS: At 12-month follow-up, 59 (83 %) and 55 (85 %) in press-fit and screw group, respectively had good-to-excellent IKDC score (p > 0.05). The mean laxity assessed using a KT-1000 arthrometer improved to 2.7 and 2.5 mm in press-fit and screw group, respectively. Regarding Lachman and pivot shift test, there was a statistically significant improvement in the integrity of the ACL in both the groups, but no significant differences was noted between groups. There were no significant differences in terms of femur circumference difference, effusion, knee range of motion, pain and complications.
CONCLUSIONS: The press-fit technique is an efficient procedure. Its outcome was comparable with the interference screw group. Furthermore it has unlimited bone-to-bone healing, no need for removal of hardware, ease for revision and cost effectiveness.

Entities:  

Mesh:

Year:  2014        PMID: 24756534     DOI: 10.1007/s00402-014-1999-3

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  The biomechanical strength of a hardware-free femoral press-fit method for ACL bone-tendon-bone graft fixation.

Authors:  M P Arnold; L D Burger; D Wirz; B Goepfert; M T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-07       Impact factor: 4.342

2.  Enhanced Bone-Tendon-Bone Approach for Open Anterior Cruciate Ligament Replacement With Conservation of the Joint Capsule.

Authors:  Sebastian Gottfried Walter; Tom Sascha Thomas; Luca Tafuro; Wolfram Thomas
Journal:  Arthrosc Tech       Date:  2015-10-26

3.  Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis.

Authors:  Ajaykumar Shanmugaraj; Mathepan Mahendralingam; Chetan Gohal; Nolan Horner; Nicole Simunovic; Volker Musahl; Kristian Samuelsson; Olufemi R Ayeni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-12       Impact factor: 4.342

4.  Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least 3 years follow-up.

Authors:  Richard Volz; Gudrun H Borchert
Journal:  Arch Orthop Trauma Surg       Date:  2022-03-15       Impact factor: 3.067

Review 5.  Comparison of Bioabsorbable and Metallic Interference Screws for Graft Fixation During ACL Reconstruction: A Meta-analysis of Randomized Controlled Trials.

Authors:  Baoyun Xu; Yuling Yin; Yanling Zhu; Yu Yin; Weili Fu
Journal:  Orthop J Sports Med       Date:  2021-08-18

6.  Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study.

Authors:  Amirhossein Borjali; Amir Nourani; Hadi Moeinnia; Mahdi Mohseni; Hossein Korani; Narges Ghias; Mahmoud Chizari
Journal:  BMC Musculoskelet Disord       Date:  2021-12-20       Impact factor: 2.362

7.  Femoral press-fit fixation versus interference screw fixation in anterior cruciate ligament reconstruction with bone-patellar tendon-bone autograft: 20-year follow-up.

Authors:  A Biazzo; A Manzotti; K Motavalli; N Confalonieri
Journal:  J Clin Orthop Trauma       Date:  2018-02-23

8.  Anterior cruciate ligament - updating article.

Authors:  Marcus Vinicius Malheiros Luzo; Carlos Eduardo da Silveira Franciozi; Fernando Cury Rezende; Guilherme Conforto Gracitelli; Pedro Debieux; Moisés Cohen
Journal:  Rev Bras Ortop       Date:  2016-06-06
  8 in total