Literature DB >> 24756426

Assessment of the hepatic veins in poor contrast conditions using dual energy CT: evaluation of a novel monoenergetic extrapolation software algorithm.

C Schabel1, M Bongers1, M Sedlmair2, A Korn3, U Grosse1, S Mangold1, C D Claussen1, C Thomas1.   

Abstract

PURPOSE: To evaluate a novel monoenergetic post-processing algorithm (MEI+) in patients with poor intrahepatic contrast enhancement.
MATERIALS AND METHODS: 25 patients were retrospectively included in this study. Late-phase imaging of the upper abdomen, which was acquired in dual-energy mode (100/140 kV), was used as a model for poor intrahepatic contrast enhancement. Traditional monoenergetic images (MEI), linearly weighted mixed images with different mixing ratios (MI), sole 100 and 140 kV and MEI+ images were calculated. MEI+ is a novel technique which applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the intrahepatic vasculature (IHV) and liver parenchyma (LP) were objectively measured and depiction of IHV was subjectively rated and correlated with portal venous imaging by two readers in consensus.
RESULTS: MEI+ was able to increase the SNR of the IHV (5.7 ± 0.4 at 40keV) and LP (4.9 ± 1.0 at 90keV) and CNR (2.1 ± 0.6 at 40keV) greatly compared to MEI (5.1 ± 1.1 at 80keV, 4.7 ± 1.0 at 80keV, 1.0 ± 0.4 at 70keV), MI (5.2 ± 1.1 M5:5, 4.8 ± 1.0 M5:5, 1.0 ± 3.5 M9:1), sole 100 kV images (4.4 ± 1.0, 3.7 ± 0.8, 1.0 ± 0.3) and 140 kV images (2.8 ± 0.5, 3.1 ± 0.6, 0.1 ± 0.2). Subjective assessment rated MEI+ of virtual 40 keV superior to all other images.
CONCLUSION: MEI+ is a very promising algorithm for monoenergetic extrapolation which is able to overcome noise limitations associated with traditional monoenergetic techniques at low virtual keV levels and consequently does not suffer from a decline of SNR and CNR at low keV values. This algorithm allows an improvement of IHV depiction in the presence of poor contrast. KEY POINTS: • The evaluated new image-based algorithm for virtual monoenergetic imaging allows calculating low virtual keV images from dual energy datasets with significantly improved contrast-to-noise ratios. • The image based novel monoenergetic extrapolation algorithm applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks.• When compared to traditional monoenergetic images, the novel monoenergetic algorithm has improved contrast-to-noise ratios for both low and high virtual keV images.• Contrast-enhanced dual energy images with poor contrast conditions can be significantly improved, e.g. late phase imaging of the liver. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24756426     DOI: 10.1055/s-0034-1366423

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  23 in total

1.  Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study.

Authors:  Stefanie Mangold; Paola M Cannaó; U Joseph Schoepf; Julian L Wichmann; Christian Canstein; Stephen R Fuller; Giuseppe Muscogiuri; Akos Varga-Szemes; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

2.  Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging.

Authors:  Martin Beeres; Jesko Trommer; Claudia Frellesen; Nour-Eldin A Nour-Eldin; Jan E Scholtz; Eva Herrmann; Thomas J Vogl; Julian L Wichmann
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-02       Impact factor: 2.357

3.  Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Julian L Wichmann; Andrew D Hardie; U Joseph Schoepf; Lloyd M Felmly; Jonathan D Perry; Akos Varga-Szemes; Stefanie Mangold; Damiano Caruso; Christian Canstein; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

Review 4.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

5.  Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography.

Authors:  Juil Park; Young Hun Choi; Jung-Eun Cheon; Woo Sun Kim; In-One Kim; Seong Yong Pak; Bernhard Krauss
Journal:  Pediatr Radiol       Date:  2017-06-27

Review 6.  Imaging of Cholangiocarcinoma.

Authors:  Susann-Cathrin Olthof; Ahmed Othman; Stephan Clasen; Christina Schraml; Konstantin Nikolaou; Malte Bongers
Journal:  Visc Med       Date:  2016-12-06

7.  Noise-optimized monoenergetic post-processing improves visualization of incidental pulmonary embolism in cancer patients undergoing single-pass dual-energy computed tomography.

Authors:  Jakob Weiss; Mike Notohamiprodjo; Malte Bongers; Christoph Schabel; Stefanie Mangold; Konstantin Nikolaou; Fabian Bamberg; Ahmed E Othman
Journal:  Radiol Med       Date:  2017-01-09       Impact factor: 3.469

8.  Comparison of virtual monoenergetic and polyenergetic images reconstructed from dual-layer detector CT angiography of the head and neck.

Authors:  Victor Neuhaus; Nils Große Hokamp; Nuran Abdullayev; Volker Maus; Christoph Kabbasch; Anastasios Mpotsaris; David Maintz; Jan Borggrefe
Journal:  Eur Radiol       Date:  2017-10-10       Impact factor: 5.315

9.  Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Johannes Kraft; Ralf W Bauer; Moritz Kaup; Patricia Dewes; Andreas M Bucher; Iris Burck; Jens Wagenblast; Thomas Lehnert; J Matthias Kerl; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

10.  Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Kristina Hüsers; Martin Beeres; Andreas M Bucher; Moritz Kaup; Simon S Martin; Sebastian Fischer; Boris Bodelle; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.