Literature DB >> 24753320

Real time visualization and characterization of platelet deposition under flow onto clinically relevant opaque surfaces.

Megan A Jamiolkowski1, Joshua R Woolley, Marina V Kameneva, James F Antaki, William R Wagner.   

Abstract

Although the thrombogenic nature of the surfaces of cardiovascular devices is an important aspect of blood biocompatibility, few studies have examined platelet deposition onto opaque materials used for these devices in real time. This is particularly true for the metallic surfaces used in current ventricular assist devices (VADs). Using hemoglobin depleted red blood cells (RBC ghosts) and long working distance optics to visualize platelet deposition, we sought to perform such an evaluation. Fluorescently labeled platelets mixed with human RBC ghosts were perfused across six opaque materials (a titanium alloy (Ti6Al4V), silicon carbide (SiC), alumina (Al2O3, 2-methacryloyloxyethyl phosphorylcholine polymer coated Ti6Al4V (MPC-Ti6Al4V), yttria partially stabilized zirconia (YZTP), and zirconia toughened alumina (ZTA)) for 5 min at wall shear rates of 400 and 1000 s(-1). Ti6Al4V had significantly increased platelet deposition relative to MPC-Ti6Al4V, Al2 O3 , YZTP, and ZTA at both wall shear rates (p < 0.01). For all test surfaces, increasing the wall shear rate produced a trend of decreased platelet adhesion. The described system can be a utilized as a tool for comparative analysis of candidate blood-contacting materials with acute blood contact.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  opaque biomaterials; platelets; red blood cell ghosts; thrombosis; ventricular assist device

Mesh:

Year:  2014        PMID: 24753320      PMCID: PMC4203704          DOI: 10.1002/jbm.a.35202

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  53 in total

Review 1.  Bleeding and thrombosis in patients with continuous-flow ventricular assist devices.

Authors:  Peter M Eckman; Ranjit John
Journal:  Circulation       Date:  2012-06-19       Impact factor: 29.690

2.  Physical and chemical effects of red cells in the shear-induced aggregation of human platelets.

Authors:  H L Goldsmith; D N Bell; S Braovac; A Steinberg; F McIntosh
Journal:  Biophys J       Date:  1995-10       Impact factor: 4.033

3.  On the Representation of Turbulent Stresses for Computing Blood Damage.

Authors:  Samuel J Hund; James F Antaki; Mehrdad Massoudi
Journal:  Int J Eng Sci       Date:  2010-11-01       Impact factor: 8.843

4.  Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand's factor.

Authors:  Wei-Bor Tsai; John M Grunkemeier; Clive D McFarland; Thomas A Horbett
Journal:  J Biomed Mater Res       Date:  2002-06-05

5.  Unexpected abrupt increase in left ventricular assist device thrombosis.

Authors:  Randall C Starling; Nader Moazami; Scott C Silvestry; Gregory Ewald; Joseph G Rogers; Carmelo A Milano; J Eduardo Rame; Michael A Acker; Eugene H Blackstone; John Ehrlinger; Lucy Thuita; Maria M Mountis; Edward G Soltesz; Bruce W Lytle; Nicholas G Smedira
Journal:  N Engl J Med       Date:  2013-11-27       Impact factor: 91.245

6.  Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; J T Baldwin; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2013-02       Impact factor: 10.247

7.  Initiation of platelet adhesion by arrest onto fibrinogen or translocation on von Willebrand factor.

Authors:  B Savage; E Saldívar; Z M Ruggeri
Journal:  Cell       Date:  1996-01-26       Impact factor: 41.582

8.  Investigation of platelet margination phenomena at elevated shear stress.

Authors:  Rui Zhao; Marina V Kameneva; James F Antaki
Journal:  Biorheology       Date:  2007       Impact factor: 1.875

9.  An extended convection diffusion model for red blood cell-enhanced transport of thrombocytes and leukocytes.

Authors:  S J Hund; J F Antaki
Journal:  Phys Med Biol       Date:  2009-10-07       Impact factor: 3.609

10.  Surface modification of biomaterials: a quest for blood compatibility.

Authors:  Achala de Mel; Brian G Cousins; Alexander M Seifalian
Journal:  Int J Biomater       Date:  2012-05-27
View more
  5 in total

1.  The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.

Authors:  Zengsheng Chen; Jiafeng Zhang; Tieluo Li; Douglas Tran; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2019-12-17       Impact factor: 3.094

2.  Visualization and analysis of biomaterial-centered thrombus formation within a defined crevice under flow.

Authors:  Megan A Jamiolkowski; Drake D Pedersen; Wei-Tao Wu; James F Antaki; William R Wagner
Journal:  Biomaterials       Date:  2016-04-26       Impact factor: 12.479

3.  Influence of shear rate and surface chemistry on thrombus formation in micro-crevice.

Authors:  Mansur Zhussupbekov; Wei-Tao Wu; Megan A Jamiolkowski; Mehrdad Massoudi; James F Antaki
Journal:  J Biomech       Date:  2021-03-26       Impact factor: 2.789

4.  Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study.

Authors:  Jacopo Biasetti; Aliaksei Pustavoitau; Pier Giorgio Spazzini
Journal:  Front Bioeng Biotechnol       Date:  2017-10-17

5.  Multi-Constituent Simulation of Thrombus Deposition.

Authors:  Wei-Tao Wu; Megan A Jamiolkowski; William R Wagner; Nadine Aubry; Mehrdad Massoudi; James F Antaki
Journal:  Sci Rep       Date:  2017-02-20       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.