Literature DB >> 24751703

A comparison between upright and supine myocardial perfusion imaging with attenuation correction.

Deborah Tout1, Christine Tonge, Peter Austin, Joanne Adams, Parthiban Arumugam.   

Abstract

OBJECTIVE: The Digirad Cardius XACT is an upright myocardial perfusion imaging (MPI) single photon emission computed tomography system offering low-dose computed tomography for attenuation correction (AC). This study compares patient acceptability and image appearance for both non-AC and AC images on the XACT with supine MPI performed on a GE Infinia Hawkeye. PATIENTS AND METHODS: A total of 47 patients [29 male patients; mean (range) BMI, 29.1 (21.0-57.5) kg/m] referred for routine MPI underwent rest and stress MPI on the XACT and Infinia. Non-AC and AC bullseye plots were created and uptake scores were recorded in each of five segments. All studies were reported by an experienced observer with clinical details available. A patient questionnaire was used to determine the relative comfort with the two systems.
RESULTS: Perfusion patterns on upright and supine non-AC images were significantly different and displayed a notable distinction between sexes. Perfusion patterns on upright and supine AC images were similar for both male and female patients, although some discrepancies between diagnostic reports still existed. A strong preference for upright imaging was demonstrated by the patient questionnaire.
CONCLUSION: Changes in soft-tissue and diaphragmatic attenuation between upright and supine MPI can be overcome with the addition of AC. However, clinicians should still ensure that they are aware of typical artefacts produced by upright and supine imaging.

Entities:  

Mesh:

Year:  2014        PMID: 24751703     DOI: 10.1097/MNM.0000000000000129

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  2 in total

1.  Effect of patient positioning on the evaluation of myocardial perfusion SPECT.

Authors:  Bertalan Kracskó; Sándor Barna; Orsolya Sántha; Anett Kiss; József Varga; Attila Forgács; Ildikó Garai
Journal:  J Nucl Cardiol       Date:  2017-03-30       Impact factor: 5.952

2.  Assessment of Myocardial CZT SPECT Recording in a Forward-Leaning Bikerlike Position.

Authors:  Mathieu Perrin; Véronique Roch; Marine Claudin; Antoine Verger; Henri Boutley; Gilles Karcher; Cédric Baumann; Nicolas Veran; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Med       Date:  2018-11-02       Impact factor: 10.057

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.