Literature DB >> 24751533

Dynamic analysis of the ulnar nerve in the cubital tunnel using ultrasonography.

Kenichi Nakano1, Keiichi Murata1, Shohei Omokawa2, Yasuaki Nakanishi1, Takamasa Shimizu1, Tsutomu Kira1, Tadanobu Onishi1, Yasuhito Tanaka1.   

Abstract

BACKGROUND: We investigated the dynamics of the ulnar nerve during elbow flexion and the relationships between these dynamics and the morphology of the ulnar nerve groove in healthy individuals.
MATERIALS AND METHODS: Twenty healthy volunteers (40 elbows) underwent ultrasonographic examination of the ulnar nerve at the elbow. We measured the breadth and depth of the ulnar nerve groove at 90° of elbow flexion and calculated the depth-to-breadth ratio. We recorded the distance from the trochlea of the humerus to the nerve and the short-axis diameter of the nerve at 30°, 60°, 90°, and 120° of elbow flexion. We calculated the medial shift and flattening of the ulnar nerve at each angle relative to 30° of flexion, compared the values among the different angles, and compared the depth-to-breadth ratio with the location, medial shift, and flattening ratio of the ulnar nerve.
RESULTS: The medial shift was significantly greater at 120° than at other angles (P < .001). Flattening increased with increasing elbow flexion and was significantly different at 60°, 90°, and 120° (all P < .001). The flattening ratios were significantly correlated with the depth-to-breadth ratio at 120° (r = -0.43, P = .005).
CONCLUSIONS: The ulnar nerve moves medially and is flattened with the elbow flexed between 90° and 120°. When the ulnar nerve groove is shallow, high degrees of elbow flexion result in flattening of the ulnar nerve in the groove.
Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Keywords:  Ultrasonography; dynamics; elbow; groove; morphology; ulnar nerve

Mesh:

Year:  2014        PMID: 24751533     DOI: 10.1016/j.jse.2014.01.039

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Ulnar nerve instability in the cubital tunnel of asymptomatic volunteers.

Authors:  Stacey M Cornelson; Roberta Sclocco; Norman W Kettner
Journal:  J Ultrasound       Date:  2019-03-12

2.  Ultrasound biomechanical anatomy of the soft structures in relation to the ulnar nerve in the cubital tunnel of the elbow.

Authors:  Paul Michelin; Grégoire Leleup; Mourad Ould-Slimane; Marie Caroline Merlet; Benjamin Dubourg; Fabrice Duparc
Journal:  Surg Radiol Anat       Date:  2017-05-29       Impact factor: 1.246

3.  Risk factors of asymptomatic reduction of motor conduction velocity of the ulnar nerve across the elbow.

Authors:  Mauro Mondelli; Palma Ciaramirato; Giuseppe Greco; Ester Pitocchi; Francesco Sicurelli; Claudia Vinciguerra
Journal:  Neurol Sci       Date:  2021-09-09       Impact factor: 3.307

4.  Anterior Subcutaneous Transposition of the Ulnar Nerve Affects Elbow Range of Motion: A Mean 13.5 Years of Follow-up.

Authors:  Xing-Hua Liu; Mao-Qi Gong; Yang Wang; Chang Liu; Shao-Liang Li; Xie-Yuan Jiang
Journal:  Chin Med J (Engl)       Date:  2018-02-05       Impact factor: 2.628

5.  Value of ultrasonography in the diagnosis of carpal tunnel syndrome-a new ultrasonographic index in carpal tunnel syndrome diagnosis: A clinical study.

Authors:  Mihaela Perţea; Sergiu Ursu; Bogdan Veliceasa; Oxana-Mădălina Grosu; Natalia Velenciuc; Sorinel Luncă
Journal:  Medicine (Baltimore)       Date:  2020-07-17       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.