Literature DB >> 24750563

Decreased granulomatous reaction by polyurethane-coated stent in the trachea.

Hikoro Matsui1, Takehiko Hiroma2, Hisaya Hasegawa3, Yoshifumi Ogiso4.   

Abstract

BACKGROUND: Reducing granulomatous reaction for stent implantation is important for the treatment of tracheobronchomalacia because formation of granuloma leads to refractory complication causing further respiratory distress. The purpose of this study was to clarify granulomatous reaction of newly innovated coated stents compared to non-coated metal stents.
METHODS: Materials and animal experiments were performed using the newly invented metallic stent (laser-cut stainless steel with a coating of polyurethane). In the materials experiment, the correlation between the holding force and deformity was tested by a compressor. In the animal examination, coated stents were orally implanted into the trachea in five rabbits, while non-coated stents were implanted in another five rabbits. After 3 weeks' observation, the inner diameter was measured by 3-D computed tomography, and the number of granulation tissues was counted by bronchofiberscope. Histological investigation followed in both groups.
RESULTS: In the materials experiment, new stents demonstrated a holding force similar to stainless steel stents. In the animal experiment, no difference was found in the inner diameter of the coated and non-coated stent groups (5.70 ± 0.17 vs 5.60 ± 0.27, P = 0.07). However, the number of granulation tissues was higher in non-coated stents than in coated stents (1.60 ± 0.55 vs 0.40 ± 0.55, P < 0.01). Histological investigation showed direct attachment of metal to the tracheal wall around the non-coated stents where epithelial structure was destroyed, while tracheal epithelia were preserved in the group of coated stents.
CONCLUSIONS: The new polyurethane-coated metallic stent maintains enough holding force, and reduces histobiological reaction to foreign bodies in this experiment.
© 2014 Japan Pediatric Society.

Entities:  

Keywords:  airway; collapse; granulation tissue; stent implantation; tracheobronchomalacia

Mesh:

Substances:

Year:  2014        PMID: 24750563     DOI: 10.1111/ped.12360

Source DB:  PubMed          Journal:  Pediatr Int        ISSN: 1328-8067            Impact factor:   1.524


  3 in total

1.  New hybrid method for trachea dilatation with rigid and flexible tools.

Authors:  Konstantinos Sapalidis; Stella Laskou; Aikaterini Amaniti; Charilaos Koulouris; Dimitrios Giannakidis; Stylianos Mantalovas; Ilias Karapantzos; Chrysa Karapantzou; Paul Zarogoulidis; Iakovos Arapakis; Haidong Huang; Chong Bai; Ioanna Kougioumtzi; Nikolaos Katsikogiannis; Eirini Sarika; Fotis Konstantinou; Wolfgang Hohenforst-Schmidt; Isaak Kesisoglou
Journal:  Respir Med Case Rep       Date:  2018-04-20

2.  Paclitaxel-Loaded PLGA Coating Stents in the Treatment of Benign Cicatrical Airway Stenosis.

Authors:  Xiaojian Qiu; Yan Liu; Jie Zhang; Ting Wang; Juan Wang
Journal:  J Clin Med       Date:  2022-01-20       Impact factor: 4.241

Review 3.  A Review of Woven Tracheal Stents: Materials, Structures, and Application.

Authors:  Chen Xu; Yanxue Ma; Haihua Huang; Zheng Ruan; Yuling Li
Journal:  J Funct Biomater       Date:  2022-07-16
  3 in total