Clinical implications of elevated HIV-1 viral load results obtained from samples stored frozen in vacutainer plasma preparation tubes.

Gavin Cloherty1, Priscilla Swanson2, Danijela Lucic3, Kevin Dieckhaus4, Paul Anthony4, Philip Cataline4, Christine Herman3, John Hackett2, Paul R Skolnik4, Lisa Chirch4.   

Abstract

Studies have demonstrated that plasma samples collected and stored frozen using vacutainer plasma preparation tubes (PPT) may result in falsely elevated viral load (VL) values with the Roche COBAS TaqMan HIV-1 v1.0 test. At the University of Connecticut Health Center, a total of 349 samples from HIV-1-infected patients on HAART were collected and stored frozen in PPT. Viral load (VL) results were obtained using the Roche COBAS TaqMan HIV-1 v2.0 test (CTM v2.0) and Abbott RealTime HIV-1 assay (RealTime HIV-1). Of the 349 samples, 260 (74.5%) had VL values that differed by >0.5log10copies/mL; 64 of these were quantified by both assays. The remaining 196 samples were detected by CTM v2.0 but not detected in RealTime HIV-1: 62 of the most discordant samples in this category (CTM v2.0 detected/RealTime HIV-1 not detected) were further analyzed using two nested RT-PCR assays targeting pol integrase: full-length (864nt) and a highly conserved subregion (134nt). No HIV-1 RNA was detected in the discordant samples, confirming RealTime HIV-1 results. The increase in VL reactivity with the CTM v2.0 assay was presumably due to proviral DNA captured by the CTM total nucleic acid extraction chemistry but not the RNA-specific extraction procedure used in RealTime HIV-1. These results suggest that using CTM v2.0 with samples frozen in PPT could have significant clinical implications for HIV-1 patient management.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HIV-1 viral load; Plasma preparation tubes

Mesh:

Substances:

Year:  2014        PMID: 24747107     DOI: 10.1016/j.jviromet.2014.01.025

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  Estimation of measurement error in plasma HIV-1 RNA assays near their limit of quantification.

Authors:  Viviane D Lima; Lu Wang; Chanson Brumme; Lang Wu; Julio S G Montaner; P Richard Harrigan
Journal:  PLoS One       Date:  2017-02-02       Impact factor: 3.240

2.  In Vitro Reactivation of Replication-Competent and Infectious HIV-1 by Histone Deacetylase Inhibitors.

Authors:  Riddhima Banga; Francesco Andrea Procopio; Matthias Cavassini; Matthieu Perreau
Journal:  J Virol       Date:  2015-12-09       Impact factor: 5.103

3.  Systematic review of the accuracy of plasma preparation tubes for HIV viral load testing.

Authors:  Robert Luo; Jessica Markby; Jilian Sacks; Lara Vojnov
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.