Literature DB >> 24746334

Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique.

Saskia W M C Maass1, Paul M H J Roekaerts2, Marcus D Lancé2.   

Abstract

OBJECTIVE: The aim of the present study was to compare 2 noninvasive cardiac output measurement methods with the continuous cardiac output thermodilution (CCO-TD) method.
DESIGN: A single-center prospective design.
SETTING: A university hospital. PARTICIPANTS: Fifty-three consecutive patients scheduled for elective, non-emergent cardiac surgery.
INTERVENTIONS: With each participant the cardiac output was measured using 3 methods: CCO-TD, the Endotracheal Cardiac Output Monitor (ECOM), and the Nexfin monitor.
MEASUREMENTS AND MAIN RESULTS: Measurements were performed simultaneously at 7 time points: After induction, before cardiopulmonary bypass, after cardiopulmonary bypass, after protamine, after arrival in the intensive care unit, and before extubation on postoperative day 1. Statistical analysis was performed using Pearson's correlation, Bland-Altman, percent error, and polar plots. Compared to CCO-TD, ECOM showed significant correlation of R0.619 with a bias of -0.13 L/min (95% confidence interval -2.19-1.93 L/min), a percent error of 40%, and trending ability of 87% and 97% within 0.5 L/min and 1.0 L/min, respectively. The Nexfin monitor showed significant correlation of R0.535 with a bias of-0.35 L/min (95% confidence interval-3.36-2.66 L/min), a percent error of 58% and trending ability of 84% and 97% were within 0.5 L/min and 1.0 L/min limits of agreement.
CONCLUSIONS: Neither the ECOM nor the Nexfin had the ability to replace the thermodilution-based continuous cardiac output monitor. The ECOM did not have acceptable accuracy or trending ability and only could be utilized for intubated patients. The Nexfin lacked reliability and trending ability. Also, the Nexfin did not provide consistent results.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Nexfin; Swan-Ganz, ECOM; cardiac output; cardiac output monitor; hemodynamic monitoring; noninvasive measurement

Mesh:

Year:  2014        PMID: 24746334     DOI: 10.1053/j.jvca.2014.01.007

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  7 in total

Review 1.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

Review 2.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

Review 3.  Understanding the Haemodynamics of Hypertension.

Authors:  B E Smith; V M Madigan
Journal:  Curr Hypertens Rep       Date:  2018-04-10       Impact factor: 5.369

4.  Comparison of Bioimpedance Versus Pulse Contour Analysis for Intraoperative Cardiac Index Monitoring in Patients Undergoing Kidney Transplantation.

Authors:  Dita Aditianingsih; Jefferson Hidayat; Vivi Medina Ginting
Journal:  Anesth Pain Med       Date:  2021-10-31

5.  Invasive and noninvasive cardiovascular monitoring options for cardiac surgery.

Authors:  Dominic P Recco; Nathalie Roy; Alexander J Gregory; Kevin W Lobdell
Journal:  JTCVS Open       Date:  2022-04-11

6.  Accuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study.

Authors:  P B W Cox; A M den Ouden; M Theunissen; L J Montenij; A G H Kessels; M D Lancé; W F F A Buhre; M A E Marcus
Journal:  Biomed Res Int       Date:  2017-10-09       Impact factor: 3.411

Review 7.  Stroke Volume Monitoring: Novel Continuous Wave Doppler Parameters, Algorithms and Advanced Noninvasive Haemodynamic Concepts.

Authors:  R A Phillips; B E Smith; V M Madigan
Journal:  Curr Anesthesiol Rep       Date:  2017-11-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.