Literature DB >> 24745630

Effect of the length of orthodontic mini-screw implants on their long-term stability: a prospective study.

Michał Sarul1, Liwia Minch, Hyo-Sang Park, Joanna Antoszewska-Smith.   

Abstract

OBJECTIVE: To analyze the influence of the length of temporary intraoral skeletal anchorage devices (TISAD/TAD) on their long-term stability in the mandible in a homogenous group of patients.
MATERIALS AND METHODS: A group of generally healthy patients of the same gender (female) and with a statistically insignificant age difference (20-29 years) highly homogenous with respect to known factors affecting the success rate of TISAD/TAD was evaluated. One type of TISAD/TAD was applied (6- or 8-mm long). Each patient received both 6- and 8-mm-long TISAD/TAD in randomly selected mandibular quadrants: left or right. The long-term success rate of TISAD/TAD was analyzed.
RESULTS: The 8-mm orthodontic mini-screw implants were significantly more stable than the 6-mm ones in the analyzed group.
CONCLUSION: The length of the TISAD/TAD may be one of the factors that can affect the long-term success rate in the mandibles of 20- to 29-year-old women.

Entities:  

Keywords:  Anchorage; Long-term stability; Mini-screw implants; TISAD/TAD

Mesh:

Substances:

Year:  2015        PMID: 24745630     DOI: 10.2319/112113-857.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites.

Authors:  M Palone; A Darsiè; G B Maino; G Siciliani; G A Spedicato; L Lombardo
Journal:  Clin Oral Investig       Date:  2021-11-27       Impact factor: 3.573

Review 2.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

3.  Evidence-based selection of orthodontic miniscrews, increasing their success rate in the mandibular buccal shelf. A randomized, prospective clinical trial.

Authors:  Michał Sarul; Joanna Lis; Hyo-Sang Park; Kornelia Rumin
Journal:  BMC Oral Health       Date:  2022-09-20       Impact factor: 3.747

4.  Optimal Implantation Site of Orthodontic Micro-Screws in the Mandibular Anterior Region Based on CBCT.

Authors:  Yannan Wang; Quan Shi; Feng Wang
Journal:  Front Physiol       Date:  2021-05-20       Impact factor: 4.566

5.  Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis.

Authors:  Hisham Mohammed; Khaled Wafaie; Mumen Z Rizk; Mohammed Almuzian; Rami Sosly; David R Bearn
Journal:  Prog Orthod       Date:  2018-09-24       Impact factor: 2.750

6.  RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period.

Authors:  Manuel Nienkemper; Jan H Willmann; Kathrin Becker; Dieter Drescher
Journal:  Prog Orthod       Date:  2020-02-17       Impact factor: 2.750

  6 in total