Establishing a normal reference range for thromboelastography in North Indian healthy volunteers.

Arulselvi Subramanian1, Venencia Albert, Renu Saxena, Deepak Agrawal, Ravindra Mohan Pandey.   

Abstract

BACKGROUND: Thromboelastography (TEG) is relatively recent assay to analyze the coagulation state of a blood sample, providing a continuous visualization of physical changes occurring during blood coagulation. There is a paucity of published literature on assessment of coagulation status using TEG in Indian population. AIM: The primary aim of the following study is to establish normal reference values for TEG in North Indian healthy volunteers and secondary aim is to compare them with conventional plasma-based routine coagulation tests and the manufacturers reference range.
MATERIALS AND METHODS: A total of 200 healthy volunteers comprised of 100 males and 100 females of age groups between 20 and 50 years, were enrolled over a period of 1 year, i.e., 2011-2012. Thromboelastometry (TEM) was performed on TEM-A automated thromboelastometer (Framar Biomedica, Rome, Italy), using whole blood non-additive (360 µl). TEG parameters analyzed were r-time, k-time, α-angle, maximal amplitude (MA). Prothrombin time (PT), activated partial thromboplastin time (aPTT) and platelet count was performed for all volunteers. The 95% reference range was calculated as (mean-1.96 standard deviation [SD]) to (mean + 1.96 SD).
RESULTS: Our reference values for 95% of 200 volunteers were r-time: 1.8-14.2 min, k-time: 0.7-7.3 min, α-angle: 27.3-72.3° and MA: 32.1-87.9 mm. Maximum clot strength was higher in women compared with men, however statistically insignificant. Overall 14.5% (29/200) of the volunteers had at least one abnormal parameter while 74% (149/200) had deranged TEG values using the manufacturer's reference range. Statistically significant variation was seen in r-time for 84.8% (P < 0.001), for k-time, in 87.1% (P < 0.001), for α-angle in 83.7% (P < 0.001) and for MA in 84% (P < 0.001), between the manufacturer and our reference range.
CONCLUSION: The efficacy of classical coagulation test has been well-established; on the contrary TEG is a fairly recent assay and its utility for patient management remains to be demonstrated. We observed TEG to be oversensitive in determining coagulopathy where there is no clinical presentation. The manufacturer's reference values may not be appropriate for different ethnicity. TEG may give an overall representation of hemostasis; however, it cannot replace the conventional coagulation tests. We recommend the determination of normal TEG values by each laboratory for their target population.

Entities:  

Mesh:

Year:  2014        PMID: 24739830     DOI: 10.4103/0377-4929.130896

Source DB:  PubMed          Journal:  Indian J Pathol Microbiol        ISSN: 0377-4929            Impact factor:   0.740


  8 in total

1.  Reference values for kaolin-activated thromboelastography in volunteers of Anhui Province in China.

Authors:  Jun-Bo Sun; Mao-Hong Bian; Tao Zhong; Ying-Yu Lu; Bang-Qiang Zhu; Hui-Qin Wen; Hai-Liang Hu
Journal:  J Clin Lab Anal       Date:  2017-01-30       Impact factor: 2.352

2.  Efficacy of Thromboelastography (TEG) in Predicting Acute Trauma-Induced Coagulopathy (ATIC) in Isolated Severe Traumatic Brain Injury (iSTBI).

Authors:  Venencia Albert; Arulselvi Subramanian; Hara Prasad Pati; Deepak Agrawal; Sanjeev Kumar Bhoi
Journal:  Indian J Hematol Blood Transfus       Date:  2018-08-11       Impact factor: 0.900

3.  Establishment of normal reference range for thromboelastography based on 17,708 cases in Beijing, China.

Authors:  Chao Wei; Jin-Yang Zhao; Shu-Ying Wang; Hui-Ning Sun; Nai-Zhe Guan
Journal:  Ann Transl Med       Date:  2022-05

4.  Reference Intervals for and the Effects of Sample Handling and Sex on Rotational Thromboelastometry in Healthy Adult Pigs.

Authors:  Guillaume L Hoareau; Anthony Barthélemy; Isabelle Goy-Thollot; Céline Pouzot-Nevoret; Carl A Beyer; Lauren E Walker; Ian J Stewart; J Kevin Grayson
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-03-23       Impact factor: 1.232

5.  Reference Intervals of Thromboelastometric Evaluation of Coagulation in Pediatric Patients with Congenital Heart Diseases: A Retrospective Investigation.

Authors:  Ji Young Kim; Yu Rim Shin; Hae Keum Kil; Mi Ran Park; Jong Wha Lee
Journal:  Med Sci Monit       Date:  2016-10-06

6.  Establishment of thromboelastography reference intervals by indirect method and relevant factor analyses.

Authors:  Daye Cheng; Xiaoying Li; Shuo Zhao; Yiwen Hao
Journal:  J Clin Lab Anal       Date:  2020-01-31       Impact factor: 2.352

7.  Establishment of the Normal Reference Range of Thrombelastogram among the Healthy Population and Pregnants in China.

Authors:  Rong Gui; Xueyuan Huang; Ming Zhou; Shujuan Ouyang; Yunfeng Fu; Hao Tang; Fengxia Liu; Rong Huang; Meng Gao; Hang Dong; Yongjun Wang
Journal:  Iran J Public Health       Date:  2019-05       Impact factor: 1.429

8.  Establishment of Normal Range for Thromboelastography in Healthy Middle-Aged and Elderly People of Weihai in China.

Authors:  Lina Ni; Peng Xue; Changjuan An; Xia Yu; Jiangli Qu; Yingjie Yao; Yingbo Li
Journal:  J Healthc Eng       Date:  2021-11-28       Impact factor: 2.682