Literature DB >> 24735504

Creation of an in vitro biomechanical model of the trachea using rapid prototyping.

Ross L Walenga1, P Worth Longest2, Gobalakrishnan Sundaresan3.   

Abstract

Previous in vitro models of the airways are either rigid or, if flexible, have not matched in vivo compliance characteristics. Rapid prototyping provides a quickly evolving approach that can be used to directly produce in vitro airway models using either rigid or flexible polymers. The objective of this study was to use rapid prototyping to directly produce a flexible hollow model that matches the biomechanical compliance of the trachea. The airway model consisted of a previously developed characteristic mouth-throat region, the trachea, and a portion of the main bronchi. Compliance of the tracheal region was known from a previous in vivo imaging study that reported cross-sectional areas over a range of internal pressures. The compliance of the tracheal region was matched to the in vivo data for a specific flexible resin by iteratively selecting the thicknesses and other dimensions of tracheal wall components. Seven iterative models were produced and illustrated highly non-linear expansion consisting of initial rapid size increase, a transition region, and continued slower size increase as pressure was increased. Thickness of the esophageal interface membrane and initial trachea indention were identified as key parameters with the final model correctly predicting all phases of expansion within a value of 5% of the in vivo data. Applications of the current biomechanical model are related to endotracheal intubation and include determination of effective mucus suctioning and evaluation of cuff sealing with respect to gases and secretions.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Compliant airway model; Endotracheal intubation; Endotracheal tube with inflatable cuff; In vitro airway experiments; Mucus leakage; Rapid prototyping

Mesh:

Year:  2014        PMID: 24735504     DOI: 10.1016/j.jbiomech.2014.03.018

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Poorly placed tracheostomy tubes: Effects on flow and resistance.

Authors:  Joshua Moorhouse; Tahir Ali; Tobias Moorhouse; David Owens
Journal:  J Intensive Care Soc       Date:  2015-04-22

Review 2.  Bridging the Gap Between Science and Clinical Efficacy: Physiology, Imaging, and Modeling of Aerosols in the Lung.

Authors:  Chantal Darquenne; John S Fleming; Ira Katz; Andrew R Martin; Jeffry Schroeter; Omar S Usmani; Jose Venegas; Otmar Schmid
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2016-02-01       Impact factor: 2.849

3.  3D printing materials and their use in medical education: a review of current technology and trends for the future.

Authors:  Justine Garcia; ZhiLin Yang; Rosaire Mongrain; Richard L Leask; Kevin Lachapelle
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2017-10-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.