Jessica Podnar1, Heather Deiderick, Gabriella Huerta, Scott Hunicke-Smith.
Abstract
This unit presents protocols for construction of next-generation sequencing (NGS) directional RNA sequencing libraries for the Illumina HiSeq and MiSeq from a wide variety of input RNA sources. The protocols are based on the New England Biolabs (NEB) small RNA library preparation set for Illumina, although similar kits exist from different vendors. The protocol preserves the orientation of the original RNA in the final sequencing library, enabling strand-specific analysis of the resulting data. These libraries have been used for differential gene expression analysis and small RNA discovery and are currently being tested for de novo transcriptome assembly. The protocol is robust and applicable to a broad range of RNA input types and RNA quality, making it ideal for high-throughput laboratories.Keywords: NGS; RNA-Seq; gene expression; library construction; strand-specific; transcriptome
Mesh:
Substances:
Year: 2014 PMID: 24733242 DOI: 10.1002/0471142727.mb0421s106
Source DB: PubMed Journal: Curr Protoc Mol Biol ISSN: 1934-3647