Literature DB >> 24729218

Real-time, in vivo determination of dynamic changes in lung and heart tissue oxygenation using EPR oximetry.

Brian K Rivera1, Shan K Naidu1, Kamal Subramanian1, Matthew Joseph1, Huagang Hou2, Nadeem Khan2, Harold M Swartz3, Periannan Kuppusamy4.   

Abstract

The use of electron paramagnetic resonance (EPR) oximetry for oxygen measurements in deep tissues (>1 cm) is challenging due to the limited penetration depth of the microwave energy. To overcome this limitation, implantable resonators, having a small (0.5 mm diameter) sensory loop containing the oxygen-sensing paramagnetic material connected by a pair of twisted copper wire to a coupling loop (8-10 mm diameter), have been developed, which enable repeated measurements of deep-tissue oxygen levels (pO2, partial pressure of oxygen) in the brain and tumors of rodents. In this study, we have demonstrated the feasibility of measuring dynamic changes in pO2 in the heart and lung of rats using deep-tissue implantable oxygen sensors. The sensory loop of the resonator contained lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) crystals embedded in polydimethylsiloxane (PDMS) polymer and was implanted in the myocardial tissue or lung pleura. The external coupling loop was secured subcutaneously above chest. The rats were exposed to different breathing gas mixtures while undergoing EPR measurements. The results demonstrated that implantable oxygen sensors provide reliable measurements of pO2 in deep tissues such as heart and lung under adverse conditions of cardiac and respiratory motions.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24729218      PMCID: PMC4330333          DOI: 10.1007/978-1-4939-0620-8_11

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   2.622


  6 in total

1.  Cerebral oxygenation of the cortex and striatum following normobaric hyperoxia and mild hypoxia in rats by EPR oximetry using multi-probe implantable resonators.

Authors:  Huagang Hou; Hongbin Li; Ruhong Dong; Sriram Mupparaju; Nadeem Khan; Harold Swartz
Journal:  Adv Exp Med Biol       Date:  2011       Impact factor: 2.622

Review 2.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

3.  Dynamic changes in oxygenation of intracranial tumor and contralateral brain during tumor growth and carbogen breathing: a multisite EPR oximetry with implantable resonators.

Authors:  Huagang Hou; Ruhong Dong; Hongbin Li; Benjamin Williams; Jean P Lariviere; S K Hekmatyar; Risto A Kauppinen; Nadeem Khan; Harold Swartz
Journal:  J Magn Reson       Date:  2011-10-01       Impact factor: 2.229

4.  Implantable resonators--a technique for repeated measurement of oxygen at multiple deep sites with in vivo EPR.

Authors:  Hongbin Li; Huagang Hou; Artur Sucheta; Benjamin B Williams; Jean P Lariviere; Md Nadeem Khan; Piotr N Lesniewski; Bernard Gallez; Harold M Swartz
Journal:  Adv Exp Med Biol       Date:  2010       Impact factor: 2.622

5.  Myocardial oxygenation and functional recovery in infarct rat hearts transplanted with mesenchymal stem cells.

Authors:  Simi M Chacko; Mahmood Khan; M Lakshmi Kuppusamy; Ramasamy P Pandian; Saradhadevi Varadharaj; Karuppaiyah Selvendiran; Anna Bratasz; Brian K Rivera; Periannan Kuppusamy
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-03-13       Impact factor: 4.733

6.  Novel particulate spin probe for targeted determination of oxygen in cells and tissues.

Authors:  Ramasamy P Pandian; Narasimham L Parinandi; Govindasamy Ilangovan; Jay L Zweier; Periannan Kuppusamy
Journal:  Free Radic Biol Med       Date:  2003-11-01       Impact factor: 7.376

  6 in total
  4 in total

Review 1.  Physiological and pathophysiological reactive oxygen species as probed by EPR spectroscopy: the underutilized research window on muscle ageing.

Authors:  Engy A Abdel-Rahman; Ali M Mahmoud; Abdulrahman M Khalifa; Sameh S Ali
Journal:  J Physiol       Date:  2016-03-17       Impact factor: 5.182

Review 2.  Relevance of Oxygen Concentration in Stem Cell Culture for Regenerative Medicine.

Authors:  Cristina Mas-Bargues; Jorge Sanz-Ros; Aurora Román-Domínguez; Marta Inglés; Lucia Gimeno-Mallench; Marya El Alami; José Viña-Almunia; Juan Gambini; José Viña; Consuelo Borrás
Journal:  Int J Mol Sci       Date:  2019-03-08       Impact factor: 5.923

Review 3.  Tumor Hypoxia Regulates Immune Escape/Invasion: Influence on Angiogenesis and Potential Impact of Hypoxic Biomarkers on Cancer Therapies.

Authors:  Raefa Abou Khouzam; Klaudia Brodaczewska; Aleksandra Filipiak; Nagwa Ahmed Zeinelabdin; Stephanie Buart; Cezary Szczylik; Claudine Kieda; Salem Chouaib
Journal:  Front Immunol       Date:  2021-01-20       Impact factor: 7.561

4.  Ultrasound Intra Body Multi Node Communication System for Bioelectronic Medicine.

Authors:  Banafsaj Jaafar; JunWen Luo; Dimitrios Firfilionis; Ahmed Soltan; Jeff Neasham; Patrick Degenaar
Journal:  Sensors (Basel)       Date:  2019-12-19       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.