Literature DB >> 24726587

Comparison of polymerization shrinkage of pattern resins.

Sarah B Gibbs1, Antheunis Versluis2, Daranee Tantbirojn3, Swati Ahuja4.   

Abstract

STATEMENT OF PROBLEM: The dimensional stability, in particular polymerization shrinkage, of pattern resins affects the accuracy of implant prosthesis fabrication. Recently introduced photopolymerizing pattern resins are easy to use, but their shrinkage needs to be determined and compared with traditional autopolymerizing pattern resins.
PURPOSE: The purpose of the study was to compare the polymerization shrinkage of photopolymerizing pattern resins with autopolymerizing pattern resins.
MATERIAL AND METHODS: Two autopolymerizing (DuraLay, GC Pattern resin) and 2 photopolymerizing (Primopattern LC Gel, Primopattern LC Paste) pattern resins were tested. The sample size was 10 for each group. Polymerization shrinkage was determined by measuring the change in area dimensions with image analysis. The percentage of volumetric shrinkage was calculated, and the results were statistically analyzed with ANOVA, followed by the Student-Newman-Keuls post hoc test (α=.05).
RESULTS: The volumetric shrinkage values (%; mean ± standard deviation) for Duralay were [corrected] 5.72 ± 0.89; for GC pattern resin, [corrected] 5.07 ± 1.36; for Primopattern LC Gel, 5.42 ± 1.83; and for Primopattern LC Paste, 7.43 ± 0.62. The volumetric shrinkage of the Primopattern LC Paste was significantly higher than that of the other 3 materials.
CONCLUSIONS: The photopolymerizing pattern resin in gel form (Primopattern LC Gel) had a similar shrinkage value to the autopolymerizing pattern resins (DuraLay and GC Pattern Resin). However, the photopolymerizing pattern resin in paste form (Primopattern LC Paste) shrank significantly more than the other 3 materials tested.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2014        PMID: 24726587     DOI: 10.1016/j.prosdent.2014.02.006

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

2.  Accuracy of several implant bite registration techniques: an in-vitro pilot study.

Authors:  Do-Hyun Park; Ji-Man Park; Jae-Won Choi; Eun-Sook Kang; Eun-Bin Bae; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

3.  Comparison of the Accuracy of Fixture-Level Implant Impression Making with Different Splinting Techniques.

Authors:  Mehrdad Nateghi; Ramin Negahdari; Sahar Molaei; Ali Barzegar; Sepideh Bohlouli
Journal:  Int J Dent       Date:  2021-10-14

4.  Customized Implant Full-Mouth Rehabilitation: A Biomechanical Depiction.

Authors:  Mukesh Kumar Singhal; Bhuwneshwer Pandey; Anshika Agarwal; Sudhir Yadav; Polysmita Ojah; Ankita Pal; Pradipto Parai
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.