Literature DB >> 24725865

Porous molecularly imprinted monolithic capillary column for on-line extraction coupled to high-performance liquid chromatography for trace analysis of antimicrobials in food samples.

Qianchun Zhang1, Xiaohua Xiao2, Gongke Li3.   

Abstract

A novel porous molecularly imprinted monolithic capillary column (MIMCC) based on ternary porogen was synthesized by in situ technique with sulfaquinoxaline as the template molecule. The characteristics of the MIMCC were investigated by scanning electron microscopy, infrared spectrum, thermogravimetric analysis and solvent resistance test. The saturated adsorption amount of sulfaquinoxaline on MIMCC was 2.7 times over that on the non-imprinted monolithic capillary column (NIMCC). The MIMCC also exhibited good enrichment ability to its analogs and the enrichment factors were 46-211 for five antimicrobials. High permeability and imprinting factors as well as good stability, reproducibility and long lifetime were obtained. An on-line method based on MIMCC solid-phase microextraction coupled with high-performance liquid chromatography was developed for the determination of trace antimicrobials in complex samples. The good linearity for sulfametoxydiazine, sulamethoxazole and sulfaquinoxaline was 0.05-10 µg/L, the limits of detection (LODs) were 10.0-14.0 ng/L. The linear range for mequindox and quinocetone were 0.10-10.0 µg/L, the LODs were 20.0-27.0 ng/L respectively. The recoveries were 71.0-108.2% with relative standard deviation of 1.6-8.5%, correspondingly. The results showed that MIMCC could effectively enrich antimicrobials from complex matrices. The on-line method based on MIMCC and HPLC was selective, sensitive and convenient for trace determination of antimicrobials in complex samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antimicrobials; Food sample; High-performance liquid chromatography; Molecularly imprinted; Monolithic capillary column; On-line extraction

Mesh:

Substances:

Year:  2014        PMID: 24725865     DOI: 10.1016/j.talanta.2014.02.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

Review 1.  Functionalized monolithic columns: Recent advancements and their applications for high-efficiency separation and enrichment in food and medicine.

Authors:  Helong Si; Quan Wang; Yuanyuan Guo; Yuxin Zhao; Hongya Li; Shuna Li; Shuxiang Wang; Baocheng Zhu
Journal:  Front Chem       Date:  2022-08-05       Impact factor: 5.545

2.  An AuNPs-Based Fluorescent Sensor with Truncated Aptamer for Detection of Sulfaquinoxaline in Water.

Authors:  Xingyue Chen; Lulan Yang; Jiaming Tang; Xu Wen; Xiaoling Zheng; Lingling Chen; Jiaqi Li; Yong Xie; Tao Le
Journal:  Biosensors (Basel)       Date:  2022-07-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.