Literature DB >> 24725135

High-resolution droplet-based fractionation of nano-LC separations onto microarrays for MALDI-MS analysis.

Simon K Küster1, Martin Pabst, Konstantins Jefimovs, Renato Zenobi, Petra S Dittrich.   

Abstract

We present a robust droplet-based device, which enables the fractionation of ultralow flow rate nanoflow liquid chromatography (nano-LC) eluate streams at high frequencies and high peak resolution. This is achieved by directly interfacing the separation column to a micro T-junction, where the eluate stream is compartmentalized into picoliter droplets. This immediate compartmentalization prevents peak dispersion during eluate transport and conserves the chromatographic performance. Subsequently, nanoliter eluate fractions are collected at a rate of one fraction per second on a high-density microarray to retain the separation with high temporal resolution. Chromatographic separations of up to 45 min runtime can thus be archived on a single microarray possessing 2700 sample spots. The performance of this device is demonstrated by fractionating the separation of a tryptic digest of a known protein mixture onto the microarray chip and subsequently analyzing the sample archive using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Resulting peak widths are found to be significantly reduced compared to standard continuous flow spotting technologies as well as in comparison to a conventional nano-LC-electrospray ionization-mass spectrometry interface. Moreover, we demonstrate the advantage of our high-definition nanofractionation device by applying two different MALDI matrices to all collected fractions in an alternating fashion. Since the information that is obtained from a MALDI-MS measurement depends on the choice of MALDI matrix, we can extract complementary information from neighboring spots containing almost identical composition but different matrices.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24725135     DOI: 10.1021/ac4041982

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

Review 1.  Microfluidics-to-mass spectrometry: a review of coupling methods and applications.

Authors:  Xue Wang; Lian Yi; Nikita Mukhitov; Adrian M Schrell; Raghuram Dhumpa; Michael G Roper
Journal:  J Chromatogr A       Date:  2014-10-23       Impact factor: 4.759

2.  Printed droplet microfluidics for on demand dispensing of picoliter droplets and cells.

Authors:  Russell H Cole; Shi-Yang Tang; Christian A Siltanen; Payam Shahi; Jesse Q Zhang; Sean Poust; Zev J Gartner; Adam R Abate
Journal:  Proc Natl Acad Sci U S A       Date:  2017-07-31       Impact factor: 11.205

3.  Enhanced protein identification using graphite-modified MALDI plates for offline LC-MALDI-MS/MS bottom-up proteomics.

Authors:  Anthony Maus; Rudolph Mignon; Franco Basile
Journal:  Anal Biochem       Date:  2018-01-08       Impact factor: 3.365

4.  A microfluidic chip for ICPMS sample introduction.

Authors:  Pascal E Verboket; Olga Borovinskaya; Nicole Meyer; Detlef Günther; Petra S Dittrich
Journal:  J Vis Exp       Date:  2015-03-05       Impact factor: 1.355

5.  A Microarray-Matrix-assisted Laser Desorption/Ionization-Mass Spectrometry Approach for Site-specific Protein N-glycosylation Analysis, as Demonstrated for Human Serum Immunoglobulin M (IgM).

Authors:  Martin Pabst; Simon Karl Küster; Fabian Wahl; Jasmin Krismer; Petra S Dittrich; Renato Zenobi
Journal:  Mol Cell Proteomics       Date:  2015-03-23       Impact factor: 5.911

6.  macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

Authors:  Kisurb Choe; Pu Xue; Huimin Zhao; Jonathan V Sweedler
Journal:  J Am Soc Mass Spectrom       Date:  2021-04-06       Impact factor: 3.109

7.  Coupling a droplet generator with conventional ESI-MS for quantitative analysis of small-volume samples.

Authors:  Meiyuan Wang; Xun Liao; Paul B Tchounwou; Yi-Ming Liu
Journal:  Anal Bioanal Chem       Date:  2022-01-21       Impact factor: 4.142

8.  Nanowell-mediated two-dimensional liquid chromatography enables deep proteome profiling of <1000 mammalian cells.

Authors:  Maowei Dou; Ying Zhu; Andrey Liyu; Yiran Liang; Jing Chen; Paul D Piehowski; Kerui Xu; Rui Zhao; Ronald J Moore; Mark A Atkinson; Clayton E Mathews; Wei-Jun Qian; Ryan T Kelly
Journal:  Chem Sci       Date:  2018-07-18       Impact factor: 9.825

9.  On-chip mass spectrometric analysis in non-polar solvents by liquid beam infrared matrix-assisted laser dispersion/ionization.

Authors:  Raphael D Urban; Tillmann G Fischer; Ales Charvat; Konstantin Wink; Benjamin Krafft; Stefan Ohla; Kirsten Zeitler; Bernd Abel; Detlev Belder
Journal:  Anal Bioanal Chem       Date:  2021-01-21       Impact factor: 4.142

10.  Bioactivity Profiling of Small-Volume Samples by Nano Liquid Chromatography Coupled to Microarray Bioassaying Using High-Resolution Fractionation.

Authors:  Barbara M Zietek; Kristina B M Still; Kevin Jaschusch; Ben Bruyneel; Freek Ariese; Tinco J F Brouwer; Matthijs Luger; Rob J Limburg; Joost C Rosier; Dick J V Iperen; Nicholas R Casewell; Govert W Somsen; Jeroen Kool
Journal:  Anal Chem       Date:  2019-08-02       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.