Literature DB >> 24724568

The additional value of three-dimensional transesophageal echocardiography in complex aortic prosthetic heart valve endocarditis.

Wilco Tanis1, Arco J Teske, Lex A van Herwerden, Steven Chamuleau, Folkert Meijboom, Ricardo P J Budde, Maarten-Jan Cramer.   

Abstract

BACKGROUND: Two-dimensional transthoracic and transesophageal echocardiography (2DTTE and 2DTEE) may fail to detect signs of prosthetic heart valve (PHV) endocarditis due to acoustic shadowing. Three-dimensional (3D) TEE may have additional value; however, data are scarce. This study was performed to investigate the additional value of 3DTEE for the detection of aortic PHV endocarditis and the extent of the disease process.
METHODS: Retrospective analysis of complex aortic PHV endocarditis cases that underwent 2DTTE, 2DTEE, and 3DTEE before surgery. Echocardiograms were individually assessed by 2 cardiologists blinded for the outcome. Surgical and pathological inspection served as the reference standard for vegetations and peri-annular extensions (abscesses/mycotic aneurysms). To determine if the proximal coronary arteries were involved in the inflammatory process as well, computed tomography angiography findings were added to reference standard.
RESULTS: Fifteen aortic PHV endocarditis cases were identified. According to the reference standard, all 15 cases had peri-annular extensions, 13 of which had a close relationship with the proximal right and/or left coronary artery. In 6 of 15 patients, a vegetation was present. Combined 2DTTE/TEE missed 1/6 vegetations and 1/15 peri-annular extensions. After addition of 3DTEE, all vegetations (6/6) and peri-annular extensions (15/15) were detected, without adding false positives. Compared to 2DTEE, in 3/15 cases, 3DTEE resulted in better delineation of the anatomical relationship of the proximal coronary arteries to the peri-annular extensions. As a result, 3DTEE had an additional value in 5/15 cases.
CONCLUSION: In complex aortic, PHV endocarditis 3DTEE may have additional value compared to 2D echocardiography.
© 2014, Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic prosthetic heart valve; endocarditis; three-dimensional transesophageal echocardiography; two-dimensional transesophageal echocardiography; two-dimensional transthoracic echocardiography

Mesh:

Year:  2014        PMID: 24724568     DOI: 10.1111/echo.12602

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  7 in total

Review 1.  Infective endocarditis in paediatric population.

Authors:  Loay Eleyan; Ameer Ahmed Khan; Gledisa Musollari; Ashwini Suresh Chandiramani; Simran Shaikh; Ahmad Salha; Abdulla Tarmahomed; Amer Harky
Journal:  Eur J Pediatr       Date:  2021-04-14       Impact factor: 3.183

2.  Three-dimensional compared to two-dimensional transesophageal echocardiography for diagnosis of infective endocarditis.

Authors:  Roman Pfister; Yann Betton; Henrik Ten Freyhaus; Norma Jung; Stephan Baldus; Guido Michels
Journal:  Infection       Date:  2016-05-17       Impact factor: 3.553

3.  Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

Authors:  Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Jeong A Kim; Jae-Kwan Song; Hwa Jung Kim; Tae-Hwan Lim; Dong Hyun Yang
Journal:  Clin Res Cardiol       Date:  2018-02-19       Impact factor: 5.460

4.  Added Value of Live 3-Dimensional Transesophageal Echocardiography During Procedures in Fontan Patients.

Authors:  S Javed Zaidi; Jamie Penk; Lorene Schweig; Vivian W Cui; Waseem Cossor; David A Roberson
Journal:  Pediatr Cardiol       Date:  2020-06-01       Impact factor: 1.655

Review 5.  Echocardiography in Infective Endocarditis: State of the Art.

Authors:  Luis Afonso; Anupama Kottam; Vivek Reddy; Anirudh Penumetcha
Journal:  Curr Cardiol Rep       Date:  2017-10-25       Impact factor: 2.931

Review 6.  Role of modern 3D echocardiography in valvular heart disease.

Authors:  Takahiro Shiota
Journal:  Korean J Intern Med       Date:  2014-10-31       Impact factor: 2.884

7.  Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings.

Authors:  Mi Yeon Park; Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Dong Hyun Yang
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2020-08-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.