BACKGROUND: Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. OBJECTIVE: To compare the image quality of three different post-contrast T1-weighted imaging techniques-standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE)-acquired in pediatric patients younger than 5 years of age. MATERIALS AND METHODS: Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. RESULTS: MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. CONCLUSIONS: Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential.
BACKGROUND: Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. OBJECTIVE: To compare the image quality of three different post-contrast T1-weighted imaging techniques-standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE)-acquired in pediatric patients younger than 5 years of age. MATERIALS AND METHODS: Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. RESULTS: MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. CONCLUSIONS: Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential.
Authors: Yiqun Xue; Jiangsheng Yu; Hyun Seon Kang; Sarah Englander; Mark A Rosen; Hee Kwon Song Journal: Magn Reson Med Date: 2011-06-07 Impact factor: 4.668
Authors: M V McConnell; V C Khasgiwala; B J Savord; M H Chen; M L Chuang; R R Edelman; W J Manning Journal: AJR Am J Roentgenol Date: 1997-05 Impact factor: 3.959
Authors: Hersh Chandarana; Tobias K Block; Andrew B Rosenkrantz; Ruth P Lim; Danny Kim; David J Mossa; James S Babb; Berthold Kiefer; Vivian S Lee Journal: Invest Radiol Date: 2011-10 Impact factor: 6.016
Authors: Saraporn Bamrungchart; Engy M Tantaway; Esin C Midia; Mateus A Hernandes; Saowanee Srirattanapong; Brian M Dale; Richard C Semelka Journal: J Magn Reson Imaging Date: 2013-02-15 Impact factor: 4.813
Authors: Ana Ferreira; Miguel Ramalho; Rafael O P de Campos; Vasco Heredia; Rafael M Azevedo; Brian Dale; Richard C Semelka Journal: J Magn Reson Imaging Date: 2011-11-29 Impact factor: 4.813