| Literature DB >> 24722839 |
Neal Carty1, Anne Wibaux2, Colleen Ward2, Daryl S Paulson3, Peter Johnson2.
Abstract
OBJECTIVES: To evaluate the antimicrobial activity of a new, transparent composite film dressing, whose adhesive contains chlorhexidine gluconate (CHG), against the native microflora present on human skin.Entities:
Keywords: IV securement; antisepsis; catheter-related infections; cutaneous flora; dressing; infection control; vascular access
Mesh:
Substances:
Year: 2014 PMID: 24722839 PMCID: PMC4100705 DOI: 10.1093/jac/dku096
Source DB: PubMed Journal: J Antimicrob Chemother ISSN: 0305-7453 Impact factor: 5.790
Figure 1.Diagram illustrating the demarcation of the back into four zones, each made up of four subsections, labelled A, B, C and D. The locations where baseline counts were taken, at the centres of each zone, are denoted BL.
Mean log reductions measured for each treatment group at each timepoint
| Timepoint | Treatment | Mean log reduction (log10 cfu/cm2) | Standard deviation (log10 cfu/cm2) | Minimum (log10 cfu/cm2) | Maximum (log10 cfu/cm2) | |
|---|---|---|---|---|---|---|
| Day 1 | CHG adhesive | 22 | 0.87 | 0.98 | −0.52 | 3.31 |
| Day 4 | CHG adhesive | 22 | 0.78 | 1.44 | −1.55 | 2.90 |
| Day 7 | CHG adhesive | 20 | 1.30 | 1.42 | −1.47 | 3.33 |
| Day 1 | control adhesive | 22 | 0.67 | 1.21 | −2.70 | 3.07 |
| Day 4 | control adhesive | 22 | −0.87 | 1.65 | −3.00 | 3.24 |
| Day 7 | control adhesive | 21 | −1.29 | 1.51 | −3.12 | 1.77 |
Results from the blocked two-factor ANOVA on the log reduction data
| Source | Degrees of freedom | Sequential sum of squares | Adjusted sum of squares | Adjusted mean square | Significancec | ||
|---|---|---|---|---|---|---|---|
| Subject | 30 | 113.761 | 97.020 | 3.234 | 2.17 | 0.003 | significant |
| Treatment | 1 | 50.188 | 50.793 | 50.793 | 34.07 | 0.000 | significant |
| Day | 2 | 19.297 | 18.916 | 9.458 | 6.34 | 0.003 | significant |
| Treatment × day | 2 | 32.166 | 32.166 | 16.083 | 10.79 | 0.000 | significant |
| Error | 93 | 138.666 | 138.666 | 1.491 | |||
| Total | 128 | 354.078 |
aAdjusted mean square value of the source divided by the adjusted mean square value of the error.
bThe P value is P(F ≥ x* | H0 true), where x* is the calculated F value.
bSignificant/not significant at α = 0.05. If the P value is ≤0.05, the test is significant. If the P value is >0.5, it is not significant.
Figure 2.Mean log reductions measured from back sites treated with either the CHG adhesive (filled circles) or the control adhesive (open circles) at each timepoint. The error bars indicate the 95% CI of the mean.