| Literature DB >> 24718956 |
Tim Tollens1, Jelle Kennes1, Koen Vermeiren1, Chris Aelvoet1.
Abstract
The purpose of this study was to show the short- and long-term results of a lightweight self-adhering mesh, Adhesix®. Between February 2011 and April 2013, we prospectively collected data of 100 consecutive patients who underwent incisional or inguinal hernia repair. Mean follow-up time was 23 months (range 7-33 months). Mean length of hospital stay was 1.7 days (range 0.5-16 days). No recurrences occurred. Pain was significantly reduced after 1 month (4.1 vs 1.6; 95% confidence interval [CI] 1.9-3.1; P < 0.0001) as well as at the last follow-up visit (1.6 vs 0.48; 95% CI 0.6-1.7; P < 0.0001). SF 36 scaled scores, as an indicator of quality of life, were good with 86, 84, 86, 84, 83, 88, 92, 87. Only 2 patients developed clinically significant seromas. No clinically significant hematomas were observed. Neither mesh nor wound infections occurred. Four patients developed urinary retention immediately postoperative, while 2 were hospitalized 2 weeks after discharge because of pneumonia. Two patients died because of unrelated causes. Based on these results, use of the Adhesix mesh seems to be safe, feasible, and efficient in hernia repair.Entities:
Mesh:
Year: 2014 PMID: 24718956
Source DB: PubMed Journal: Surg Technol Int ISSN: 1090-3941