Literature DB >> 24718115

High speed, wide velocity dynamic range Doppler optical coherence tomography (Part IV): split spectrum processing in rotary catheter probes.

Barry Vuong, Anthony M D Lee, Timothy W H Luk, Cuiru Sun, Stephen Lam, Pierre Lane, Victor X D Yang.   

Abstract

We report a technique for blood flow detection using split spectrum Doppler optical coherence tomography (ssDOCT) that shows improved sensitivity over existing Doppler OCT methods. In ssDOCT, the Doppler signal is averaged over multiple sub-bands of the interferogram, increasing the SNR of the Doppler signal. We explore the parameterization of this technique in terms of number of sub-band windows, width and overlap of the windows, and their effect on the Doppler signal to noise in a flow phantom. Compared to conventional DOCT, ssDOCT processing has increased flow sensitivity. We demonstrate the effectiveness of ssDOCT in-vivo for intravascular flow detection within a porcine carotid artery and for microvascular vessel detection in human pulmonary imaging, using rotary catheter probes. To our knowledge, this is the first report of visualizing in-vivo Doppler flow patterns adjacent to stent struts in the carotid artery.

Entities:  

Mesh:

Year:  2014        PMID: 24718115     DOI: 10.1364/OE.22.007399

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  7 in total

1.  Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system: erratum.

Authors:  Simon S Gao; Gangjun Liu; David Huang; Yali Jia
Journal:  Opt Lett       Date:  2016-02-01       Impact factor: 3.776

2.  Developing cross-correlation as a method for microvessel imaging using clinical intravascular optical coherence tomography systems.

Authors:  Shiju Joseph; Asif Adnan; Hrebesh M Subhash; Martin Leahy; David Adlam
Journal:  Biomed Opt Express       Date:  2015-02-03       Impact factor: 3.732

3.  En face Doppler total retinal blood flow measurement with 70 kHz spectral optical coherence tomography.

Authors:  Ou Tan; Gangjun Liu; Liu Liang; Simon S Gao; Alex D Pechauer; Yali Jia; David Huang
Journal:  J Biomed Opt       Date:  2015-06       Impact factor: 3.170

4.  Comparison of amplitude-decorrelation, speckle-variance and phase-variance OCT angiography methods for imaging the human retina and choroid.

Authors:  Iwona Gorczynska; Justin V Migacz; Robert J Zawadzki; Arlie G Capps; John S Werner
Journal:  Biomed Opt Express       Date:  2016-02-19       Impact factor: 3.732

5.  Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system.

Authors:  Simon S Gao; Gangjun Liu; David Huang; Yali Jia
Journal:  Opt Lett       Date:  2015-05-15       Impact factor: 3.776

6.  Evaluation of flow velocities after carotid artery stenting through split spectrum Doppler optical coherence tomography and computational fluid dynamics modeling.

Authors:  Barry Vuong; Helen Genis; Ronnie Wong; Joel Ramjist; Jamil Jivraj; Hamza Farooq; Cuiru Sun; Victor X D Yang
Journal:  Biomed Opt Express       Date:  2014-11-26       Impact factor: 3.732

Review 7.  Optical Coherence Tomography Angiography.

Authors:  Simon S Gao; Yali Jia; Miao Zhang; Johnny P Su; Gangjun Liu; Thomas S Hwang; Steven T Bailey; David Huang
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-07-01       Impact factor: 4.799

  7 in total