Literature DB >> 24714008

Comparison of intravenous colloid and colloid-crystalloid combination in hypotension prophylaxis during spinal anesthesia for cesarean section.

H O Idehen1, F E Amadasun, I T Ekwere.   

Abstract

CONTEXT: Many studies comparing different intravenous fluid types usually do not use equipotent volumes of three to one crystalloid to colloid ratio in such comparisons. Conflicting results emanate from such studies. AIM: This study was designed to compare the efficacy of equipotent volumes of colloid and crystalloid-colloid combination in spinal anesthesia-induced hypotension prophylaxis during cesarean section. SETTINGS AND
DESIGN: A prospective randomized double blinded experimental study carried out in a tertiary hospital in Nigeria.
MATERIALS AND METHODS: Pregnant women scheduled for elective cesarean section were prospectively randomized into two groups to receive either 1000 ml of crystalloid/colloid (750/250 ml) combination or 500 ml colloid intravenous fluid preload, before spinal anesthesia. Hemodynamic variables were monitored till the end of surgery. The results were collated, analyzed, and rational conclusions deduced. STATISTICAL ANALYSIS USED: Data collected and analyzed with Statistical Package for Social Sciences (SPSS) version 16 and rational deductions derived.
RESULTS: In the first 10 min, the crystalloid-colloid combination showed better efficacy in hypotension prophylaxis over the colloid only regimen. In the next 30 min; however, there was no significant difference between both groups in hemodynamic parameters.
CONCLUSION: Beyond 10 min the crystalloid-colloid combination has no advantage over colloid alone in hypotension prophylaxis, as used in this study.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24714008     DOI: 10.4103/1119-3077.130231

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  4 in total

1.  Techniques for preventing hypotension during spinal anaesthesia for caesarean section.

Authors:  Cheryl Chooi; Julia J Cox; Richard S Lumb; Philippa Middleton; Mark Chemali; Richard S Emmett; Scott W Simmons; Allan M Cyna
Journal:  Cochrane Database Syst Rev       Date:  2020-07-01

2.  Association of hemodynamics during caesarean section, outcomes after caesarean section and hormone changes with different anesthesia in pregnant women with severe pulmonary arterial hypertension.

Authors:  Yun Wang; Haiyan Xu; Haiyan Li; Yan Liu; Qingling Bai
Journal:  Exp Ther Med       Date:  2018-03-27       Impact factor: 2.447

3.  Comparison of the effects of colloid preload, vasopressor administration and leg compression on hemodynamic changes during spinal anesthesia for lumbar disc surgery in knee-chest position.

Authors:  Reihanak Talakoub; Abdolrahman Fani; Anahita Hirmanpour
Journal:  Adv Biomed Res       Date:  2015-08-31

4.  Six percent hetastarch versus lactated Ringer's solution - for preloading before spinal anesthesia for cesarean section.

Authors:  Madhusudan Upadya; Sonal Bhat; Seema Paul
Journal:  Anesth Essays Res       Date:  2016 Jan-Apr
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.