| Literature DB >> 24713025 |
J Taylor1, C Shrubsole, M Davies, P Biddulph, P Das, I Hamilton, S Vardoulakis, A Mavrogianni, B Jones, E Oikonomou.
Abstract
UNLABELLED: A number of studies have estimated population exposure to PM2.5 by examining modeled or measured outdoor PM2.5 levels. However, few have taken into account the mediating effects of building characteristics on the ingress of PM2.5 from outdoor sources and its impact on population exposure in the indoor domestic environment. This study describes how building simulation can be used to determine the indoor concentration of outdoor-sourced pollution for different housing typologies and how the results can be mapped using building stock models and Geographical Information Systems software to demonstrate the modifying effect of dwellings on occupant exposure to PM2.5 across London. Building archetypes broadly representative of those in the Greater London Authority were simulated for pollution infiltration using EnergyPlus. In addition, the influence of occupant behavior on indoor levels of PM2.5 from outdoor sources was examined using a temperature-dependent window-opening scenario. Results demonstrate a range of I/O ratios of PM2.5 , with detached and semi-detached dwellings most vulnerable to high levels of infiltration. When the results are mapped, central London shows lower I/O ratios of PM2.5 compared with outer London, an apparent inversion of exposure most likely caused by the prevalence of flats rather than detached or semi-detached properties. PRACTICAL IMPLICATIONS: Population exposure to air pollution is typically evaluated using the outdoor concentration of pollutants and does not account for the fact that people in London spend over 80% of their time indoors. In this article, building simulation is used to model the infiltration of outdoor PM2.5 into the domestic indoor environment for dwellings in a London building stock model, and the results mapped. The results show the variation in relative vulnerability of dwellings to pollution infiltration, as well as an estimated absolute indoor concentration across the Greater London Authority (GLA) scaled by local outdoor levels. The practical application of this work is a better understanding of the modifying effect of the building geometry and envelope design on pollution exposure, and how the London building stock may alter exposure. The results will be used to inform population exposure to PM2.5 in future environmental epidemiological studies.Entities:
Keywords: Building stock model; EnergyPlus; Geographical information systems; Indoor air quality; PMzzm3219902.5
Mesh:
Substances:
Year: 2014 PMID: 24713025 PMCID: PMC4278446 DOI: 10.1111/ina.12116
Source DB: PubMed Journal: Indoor Air ISSN: 0905-6947 Impact factor: 5.770
Figure 1Research area: Greater London. Areas without dwelling information are shown in gray
Figure 2Research workflow and data inputs
Dwelling archetype descriptions and permeability estimated from the EHS and SAP
| Archetype code | Dwelling archetype | Age bracket | Frequency in stock, % | Estimated permeability (m3/h/m2 at 50 Pa) |
|---|---|---|---|---|
| H01 | Late Victorian/Edwardian Terrace (Large T) | 1902–1913 | 15.4 | 17.2 |
| H02 | WW1 & WW2 Simple Terrace | 1914–1945 | 14.5 | 14.9 |
| H03 | WW1 & WW2 Large Semidetached | 1914–1945 | 8.8 | 16.1 |
| H04 | ‘60s & ‘70s Tall Purpose-built Flats | 1960–1979 | 5.7 | 16.2 |
| H05 | Late Victorian/Edwardian Simple Terrace | 1902–1913 | 5.5 | 17.2 |
| H06 | Post-War Tall Purpose-built Flats | 1946–1959 | 4.7 | 13.2 |
| H07 | Recent Tall Purpose-built Flats | 1980–2008 | 3.6 | 9.2 |
| H08 | Late Victorian/Edwardian Simple Terrace (attic) | 1902–1913 | 2.9 | 17.2 |
| H09 | WW1 & WW2 Bungalow | 1914–1945 | 2.4 | 17.9 |
| H10 | ‘60s & ‘70s Simple Terrace | 1960–1979 | 2.4 | 12.3 |
| H11 | ‘60s & ‘70s Line-built Walk-up Flats | 1960–1979 | 2.3 | 9.8 |
| H12 | WW1 & WW2 Line-built Walk-up Flats | 1914–1945 | 2.1 | 10.1 |
| H13 | Recent Terrace with Shop Below | 1980–2008 | 2.1 | 12.2 |
| H14 | Post-War Step-Linked Terrace | 1946–1959 | 1.9 | 13.4 |
| H15 | Post-War Line-built Walk-up Flats | 1946–1959 | 1.8 | 11.6 |
Figure 3Estimated outdoor PM2.5 concentrations in Greater London for 2010 (DEFRA, 2011)
Figure 4Average monthly PM2.5 I/O ratios for the bungalow living room under scenarios 1 and 2 (modeled with trickle vents), and monthly variation in London background PM2.5 levels (London Air, 2014)
Figure 5The seasonal average I/O ratio of PM2.5 pollution from outdoor sources, weighted according to room occupancy schedule and estimated frequency of trickle vents
Figure 6Seasonal average I/O PM2.5 ratios for dwellings across London for Scenario 1 and Scenario 2
Figure 7Estimated absolute indoor PM2.5 concentrations from outdoor sources, based on I/O ratio (Scenario 1) and estimated temporal and spatial variations in outdoor concentrations. The inset shows outdoor concentrations from Figure3
Figure 8Estimated absolute indoor PM2.5 concentrations from outdoor sources, based on I/O ratio (Scenario 2) and estimated temporal and spatial variations in outdoor concentrations. The inset shows outdoor concentrations from Figure3