Literature DB >> 24710506

Assessing bolus retention in achalasia using high-resolution manometry with impedance: a comparator study with timed barium esophagram.

Yu K Cho1, Anna M Lipowska2, Frédéric Nicodème3, Ezra N Teitelbaum4, Eric S Hungness4, Elyse R Johnston2, Andrew Gawron2, Peter J Kahrilas2, John E Pandolfino2.   

Abstract

OBJECTIVES: The aim of this study was to assess whether high-resolution impedance manometry (HRIM) could be used to assess bolus retention similar to the timed barium esophagram (TBE).
METHODS: Twenty achalasia patients (10 males, aged 21-79 years) were prospectively evaluated with HRIM and TBE to determine the correlation between barium column height and the impedance bolus height (IBH). The TBE protocol used a 200-ml barium challenge and the HRIM protocol used a 200-ml saline challenge protocol. Both protocols were performed in an upright position and the heights of the barium and impedance columns were measured at 1 and 5 min. Analysis of IBH was performed with a topographic technique and a spatial impedance variation plot.
RESULTS: There was no significant difference between the median IBH and barium column at 1 min (IBH: 12.0 cm (interquartile range (IQR), 8.0-18.0); TBE: 12.0 cm (IQR, 7.0-19.0); P=0.90) or at 5 min (IBH: 11.0 cm (IQR, 1.0-17.0); TBE: 9.0 cm (IQR, 4.0-12.0); P=0.47). In addition, the correlation between the two measurements at 1 and 5 min was 0.60 and 0.86, respectively. Using a barium column or impedance height of >5.0 as a definition of bolus retention was associated with 75% concordance at 1 min and 95% concordance at 5 min.
CONCLUSIONS: There was excellent agreement between TBE and high-resolution impedance manometry (HRIM) for assessing bolus retention at 5 min. Thus, HRM with impedance may be used as a single test to assess bolus retention and motor function in the management of achalasia.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24710506      PMCID: PMC4307753          DOI: 10.1038/ajg.2014.61

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  17 in total

Review 1.  AGA technical review on the clinical use of esophageal manometry.

Authors:  John E Pandolfino; Peter J Kahrilas
Journal:  Gastroenterology       Date:  2005-01       Impact factor: 22.682

2.  Clearance mechanisms of the aperistaltic oesophagus: the "pump gun" hypothesis.

Authors:  R Tutuian; D Pohl; D O Castell; M Fried
Journal:  Gut       Date:  2005-12-14       Impact factor: 23.059

3.  Assessment of oesophageal emptying in achalasia patients by intraluminal impedance monitoring.

Authors:  J M Conchillo; M Selimah; A J Bredenoord; M Samsom; A J P M Smout
Journal:  Neurogastroenterol Motil       Date:  2006-11       Impact factor: 3.598

4.  Multiple rapid swallowing in idiopathic achalasia: from conventional to high resolution manometry.

Authors:  M Fox
Journal:  Neurogastroenterol Motil       Date:  2007-09       Impact factor: 3.598

5.  Uncovering hidden information in achalasia using esophageal pressure topography.

Authors:  John E Pandolfino
Journal:  Gastroenterology       Date:  2013-02-26       Impact factor: 22.682

6.  A unique esophageal motor pattern that involves longitudinal muscles is responsible for emptying in achalasia esophagus.

Authors:  Su Jin Hong; Valmik Bhargava; Yanfen Jiang; Debbie Denboer; Ravinder K Mittal
Journal:  Gastroenterology       Date:  2010-04-08       Impact factor: 22.682

Review 7.  Chicago classification criteria of esophageal motility disorders defined in high resolution esophageal pressure topography.

Authors:  A J Bredenoord; M Fox; P J Kahrilas; J E Pandolfino; W Schwizer; A J P M Smout
Journal:  Neurogastroenterol Motil       Date:  2012-03       Impact factor: 3.598

8.  Timed barium oesophagram: better predictor of long term success after pneumatic dilation in achalasia than symptom assessment.

Authors:  M F Vaezi; M E Baker; E Achkar; J E Richter
Journal:  Gut       Date:  2002-06       Impact factor: 23.059

Review 9.  Treatment and surveillance strategies in achalasia: an update.

Authors:  Alexander J Eckardt; Volker F Eckardt
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2011-04-26       Impact factor: 46.802

10.  Combined multichannel intraluminal impedance and manometry clarifies esophageal function abnormalities: study in 350 patients.

Authors:  Radu Tutuian; Donald O Castell
Journal:  Am J Gastroenterol       Date:  2004-06       Impact factor: 10.864

View more
  20 in total

Review 1.  Advances in Management of Esophageal Motility Disorders.

Authors:  Peter J Kahrilas; Albert J Bredenoord; Dustin A Carlson; John E Pandolfino
Journal:  Clin Gastroenterol Hepatol       Date:  2018-04-24       Impact factor: 11.382

Review 2.  Utility of Esophageal High-Resolution Manometry in Clinical Practice: First, Do HRM.

Authors:  Ishita Dhawan; Brendon O'Connell; Amit Patel; Ron Schey; Henry P Parkman; Frank Friedenberg
Journal:  Dig Dis Sci       Date:  2018-12       Impact factor: 3.199

3.  Self-medication of achalasia with cannabis, complicated by a cannabis use disorder.

Authors:  Amandine Luquiens; Nelson Lourenco; Amine Benyamina; Henri-Jean Aubin
Journal:  World J Gastroenterol       Date:  2015-05-28       Impact factor: 5.742

Review 4.  Achalasia: It Is Not All Black and White.

Authors:  Santosh Sanagapalli; Rami Sweis
Journal:  Curr Gastroenterol Rep       Date:  2017-06

Review 5.  How to Optimally Apply Impedance in the Evaluation of Esophageal Dysmotility.

Authors:  Amit Patel; C Prakash Gyawali
Journal:  Curr Gastroenterol Rep       Date:  2016-11

Review 6.  Oesophageal dysphagia: manifestations and diagnosis.

Authors:  Frank Zerbib; Taher Omari
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2014-11-18       Impact factor: 46.802

7.  Correlation Between Timed Barium Esophagogram and Esophageal Transit Scintigraphy Results in Achalasia.

Authors:  Yoo Mi Park; Han Ho Jeon; Jae Jun Park; Jie-Hyun Kim; Young Hoon Youn; Hyojin Park
Journal:  Dig Dis Sci       Date:  2015-04-30       Impact factor: 3.199

8.  Roles of High-resolution Manometry in Predicting Incomplete Bolus Transit in Patients With Dysphagia.

Authors:  Zhaohong Shi; Jie Guo; John Clarke; Haifeng Jin; Xinjun Wang; Nina Zhang; Ellen Stein; Sameer Dhalla; Pankaj J Pasricha; Jiande D Z Chen
Journal:  J Clin Gastroenterol       Date:  2018-10       Impact factor: 3.062

Review 9.  High-resolution manometry in diagnosis and treatment of achalasia: help or hype.

Authors:  Joel E Richter
Journal:  Curr Gastroenterol Rep       Date:  2014-12

10.  High-Resolution Manometry in Clinical Practice.

Authors:  Dustin A Carlson; John E Pandolfino
Journal:  Gastroenterol Hepatol (N Y)       Date:  2015-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.