Literature DB >> 24709812

Second glaucoma drainage devices in refractory pediatric glaucoma: failure by fibrovascular ingrowth.

Irene Tung1, Inna Marcus1, Warakorn Thiamthat1, Sharon F Freedman2.   

Abstract

PURPOSE: To evaluate initial glaucoma drainage device failure and subsequent glaucoma drainage device placement for refractory pediatric glaucoma.
DESIGN: Retrospective interventional case series.
METHODS: The Duke University surgical records from a single surgeon from 1997 to 2012 were reviewed for patients having at least 2 glaucoma drainage devices for refractory pediatric glaucoma. Data collected included glaucoma diagnosis, age at surgery, surgical interventions, preoperative/postoperative IOP and medications, and complications. Failure was defined as having an IOP >21 mm Hg (or clinically inadequate), and/or IOP-reducing surgery/devastating complication.
RESULTS: Forty-three eyes (37 patients) had 2 or more glaucoma drainage devices. Mean age at second glaucoma drainage device implantation was 9.2 ± 7.1 years, with mean IOP 30 ± 11 mm Hg, on 3 ± 1 IOP-lowering medications. Fibrovascular ingrowth was documented during second glaucoma drainage device surgery in 12 of 43 eyes (28%), occurring only in Ahmed devices, at a mean of 70 months (range 11-153) after initial implantation. Failure of the second glaucoma drainage device surgery occurred in 18 of 43 eyes (42%) at mean 26.1 ± 32.2 months (median 19.3 months). Surgical success of second glaucoma drainage devices (Kaplan-Meier analysis) at 1 year, 2 years, and 3 years was 81%, 62%, and 50%, respectively.
CONCLUSIONS: Single glaucoma drainage device surgery fails to control IOP in some eyes with refractory pediatric glaucoma. Second glaucoma drainage device implantation offers a treatment option with modest success over time. Fibrovascular ingrowth should be suspected as a relatively common cause of IOP elevation and failure after Ahmed device implantation.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24709812     DOI: 10.1016/j.ajo.2014.03.017

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  A novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration.

Authors:  Ian Grierson; Don Minckler; Marian K Rippy; Andrew J Marshall; Nathalie Collignon; Jessica Bianco; Benoit Detry; Murray A Johnstone
Journal:  BMC Biomed Eng       Date:  2020-10-14

2.  A Surgical Approach to Pediatric Glaucoma.

Authors:  Arif O Khan
Journal:  Open Ophthalmol J       Date:  2015-05-15

3.  Ologen augmentation of Ahmed glaucoma drainage devices in pediatric glaucomas.

Authors:  Adam Jacobson; Carin Rojas; Brenda L Bohnsack
Journal:  BMC Ophthalmol       Date:  2021-02-05       Impact factor: 2.209

4.  Evaluation of success after second Ahmed glaucoma valve implantation.

Authors:  Naveed Nilforushan; Maryam Yadgari; Anis Alsadat Jazayeri; Nasser Karimi
Journal:  Indian J Ophthalmol       Date:  2016-03       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.