Literature DB >> 24709742

Tibial Stress Fracture Secondary to Half-Pins in Circular Ring External Fixation for Charcot Foot.

Carroll P Jones1, Cdr Scot A Youngblood2, Norman Waldrop3, W Hodges Davis1, Michael S Pinzur4.   

Abstract

BACKGROUND: There is an increasing trend for surgical correction of the deformity associated with Charcot neuroarthropathy of the foot and ankle (Charcot foot) in order to allow ambulation with commercially available therapeutic footwear. The significant rate of surgical and medical morbidity associated with extensive conventional operative correction has led many surgeons to use limited surgical dissection and stabilization with circular ring external fixation.
METHODS: A retrospective chart review was performed on 254 patients at 2 academic medical centers who underwent surgical correction for diabetes-associated Charcot foot deformity with limited soft tissue dissection and stabilization accomplished with a statically applied circular external fixator. Tibial stress fractures developed in 10 of the patients.
RESULTS: Seven of the fractures developed in the 42 patients in whom tibial block fixation was accomplished with half-pins (16.7%), and 3 fractures developed in the 202 patients in whom tibial block fixation was accomplished with tensioned fine wires (1.5%). Three of the tibial stress fractures were successfully treated with extension of the circular frame above the level of the stress fracture. Four fractures were successfully treated with closed intramedullary nailing and 3 with weight-bearing total contact casts. Two tibial fractures occurred through pin sites (all half-pins) in 120 nonneuropathic patients who underwent application of circular ring external fixators during the same 6-year period.
CONCLUSION: Tibial stress fracture is an unusual complication associated with the use of circular ring external fixation. This investigation highlights the significantly greater risk for the development of this complication in diabetic patients undergoing surgical correction for Charcot foot deformity when half-pins are used for tibial block stabilization, compared with tensioned fine wires. We now recommend the universal use of tensioned fine wires for tibial block fixation when circular ring fixation is performed in patients with Charcot foot arthropathy. LEVEL OF EVIDENCE: Level IV, retrospective case series.

Entities:  

Keywords:  biomechanics; diabetes

Year:  2014        PMID: 24709742     DOI: 10.1177/1071100714531229

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  3 in total

1.  [Management of midfoot instability in Charcot foot with the ring fixator : Use of a hybrid technique with internal and external stabilization].

Authors:  S Kriegelstein; C Volkering; S Altenberger; S Kessler; M Walther
Journal:  Oper Orthop Traumatol       Date:  2015-04-10       Impact factor: 1.154

2.  Hybrid Fixation for Paediatric Femoral Supracondylar Fracture during Circular External Fixation of the Lower Limb.

Authors:  Yoshinobu Oka; Wook-Cheol Kim; Takashi Yoshida; Masashi Nakase; Yoshihiro Kotoura; Atsushi Nishida; Hiroaki Wada; Toshiharu Shirai; Kenji Takahashi
Journal:  Strategies Trauma Limb Reconstr       Date:  2020 Sep-Dec

3.  Improved Ilizarov method for management of deformity and ulceration on foot and ankle of spina bifida.

Authors:  Jiancheng Zang; Anatoliy Sergeyevich Sudnitsyn; Zhongjun Mo; Shaofeng Jiao; Lei Shi; Liwei Zhao; Junchao Guo; Artem Mihailovich Ermakov; Nikolay Mikhailovich Kliushin; Alexander Gubin; Sihe Qin
Journal:  J Orthop Translat       Date:  2021-04-07       Impact factor: 5.191

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.