Literature DB >> 24708084

Paper-based ELISA for the detection of autoimmune antibodies in body fluid-the case of bullous pemphigoid.

Chao-Kai Hsu1, Hsin-Yu Huang, Wan-Rung Chen, Wataru Nishie, Hideyuki Ujiie, Ken Natsuga, Shu-Ting Fan, Hsi-Kai Wang, Julia Yu-Yun Lee, Wei-Lun Tsai, Hiroshi Shimizu, Chao-Min Cheng.   

Abstract

Bullous pemphigoid (BP), a common autoimmune blistering disease, is increasing in incidence and conveys a high mortality. Detection of autoantibodies targeting the noncollagenous 16A (NC16A) domain of type XVII collagen using enzyme-linked immunosorbent assay (ELISA) has demonstrated high sensitivity and specificity for diagnosing BP. We have developed a rapid, low-cost, and widely applicable ELISA-based system to detect the NC16A autoimmune antibody and then diagnose and monitor BP disease activity using a piece of filter paper, a wax-printer, and NC16A antigens. Both sera and/or blister fluids from 14 untreated BP patients were analyzed. The control group included healthy volunteers and patients with other blistering disorders such as pemphigus vulgaris. In our established paper-based ELISA (P-ELISA) system, only 2 μL of serum or blister fluid and 70 min were required to detect anti-NC16A autoimmune antibodies. The relative color intensity was significantly higher in the BP group than in the control groups when using either serum (P < 0.05) or blister fluid (P < 0.001) specimens from BP patients. The results of P- ELISA were moderately correlated with the titer of the commercial ELISA kit (MBL, Japan) (rho = 0.5680, P = 0.0011). This newly developed system allows for rapid and convenient diagnosis and/or monitoring of BP disease activity.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24708084     DOI: 10.1021/ac500835k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

1.  A microfluidic platform with digital readout and ultra-low detection limit for quantitative point-of-care diagnostics.

Authors:  Ying Li; Jie Xuan; Yujun Song; Ping Wang; Lidong Qin
Journal:  Lab Chip       Date:  2015-08-21       Impact factor: 6.799

Review 2.  Gold Nanoparticles for In Vitro Diagnostics.

Authors:  Wen Zhou; Xia Gao; Dingbin Liu; Xiaoyuan Chen
Journal:  Chem Rev       Date:  2015-06-26       Impact factor: 60.622

3.  Colored wax-printed timers for two-dimensional and three-dimensional assays on paper-based devices.

Authors:  Chen-Hsun Weng; Ming-Yi Chen; Chi-Hsiang Shen; Ruey-Jen Yang
Journal:  Biomicrofluidics       Date:  2014-11-18       Impact factor: 2.800

4.  Multiple enzyme-doped thread-based microfluidic system for blood urea nitrogen and glucose detection in human whole blood.

Authors:  Yu-An Yang; Che-Hsin Lin
Journal:  Biomicrofluidics       Date:  2015-03-20       Impact factor: 2.800

5.  Ion concentration polarization on paper-based microfluidic devices and its application to preconcentrate dilute sample solutions.

Authors:  Ruey-Jen Yang; Hao-Hsuan Pu; Hsiang-Li Wang
Journal:  Biomicrofluidics       Date:  2015-02-18       Impact factor: 2.800

6.  Competitive volumetric bar-chart chip with real-time internal control for point-of-care diagnostics.

Authors:  Ying Li; Jie Xuan; Tom Xia; Xin Han; Yujun Song; Zheng Cao; Xin Jiang; Yi Guo; Ping Wang; Lidong Qin
Journal:  Anal Chem       Date:  2015-03-18       Impact factor: 6.986

Review 7.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

8.  Paper-based diagnostic devices for clinical paraquat poisoning diagnosis.

Authors:  Chen-Meng Kuan; Szu-Ting Lin; Tzung-Hai Yen; Yu-Lin Wang; Chao-Min Cheng
Journal:  Biomicrofluidics       Date:  2016-06-21       Impact factor: 2.800

9.  Smartphone Detection of UV LED-Enhanced Particle Immunoassay on Paper Microfluidics.

Authors:  Tu San Park; Soohee Cho; Tigran G Nahapetian; Jeong-Yeol Yoon
Journal:  SLAS Technol       Date:  2016-07-10       Impact factor: 3.047

Review 10.  Point-of-care (POC) devices by means of advanced MEMS.

Authors:  Stanislav L Karsten; Mehmet C Tarhan; Lili C Kudo; Dominique Collard; Hiroyuki Fujita
Journal:  Talanta       Date:  2015-04-23       Impact factor: 6.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.