Literature DB >> 24707990

Benefit of cone-beam CT angiography in visualizing aneurysm shape and identification of exact rupture site.

Alexandra Lauric1, Robert S Heller, Sarah Schimansky, Adel M Malek.   

Abstract

While high-resolution cone-beam computational tomographic (CBCT) angiography has gained use in intracranial vascular imaging, digital subtraction angiography (DSA) and 3-dimensional-rotational angiography (3D-RA) remain the preferred acquisition modalities for intracranial aneurysm imaging. This case report highlights the utility of the greater spatial resolution afforded by CBCT for cerebral aneurysm imaging. A 54-year-old man presenting with subarachnoid hemorrhage was confirmed to harbor a ruptured anterior communicating artery aneurysm by conventional angiography. Due to varying contrast opacification captured by different acquisition methods, dramatic aneurysm shape difference was observed between 2- and 3-dimensional-angiographic and CBCT models. The greater resolution of CBCT revealed in an unequivocal fashion the exact site of rupture on the aneurysm dome, visualized as a discrete irregular and elongated bleb that was not seen on either 3D-RA or DSA. High-resolution CBCT visualized the shape of the target aneurysm in greater detail than the more conventional 2D-DSA and 3D-RA, enabling more precise computational fluid dynamics (CFD) simulations. Given that aneurysms most likely change shape either prior to rupture or upon rupture, future studies evaluating fluid dynamics using computer reconstructions should be cognizant of the differences in resolution provided by various imaging modalities.
Copyright © 2014 by the American Society of Neuroimaging.

Entities:  

Keywords:  Intracranial aneurysm; computational fluid dynamics; cone-beam computed tomography; rupture site; subarachnoid hemorrhage; wall shear stress

Mesh:

Year:  2014        PMID: 24707990     DOI: 10.1111/jon.12120

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  3 in total

1.  Cone beam computed tomography improves the detection of injured vessels and involved vascular territories in patients with bleeding of uncertain origin.

Authors:  Ulrich Grosse; Roland Syha; Dominik Ketelsen; Rüdiger Hoffmann; Sasan Partovi; Tarun Mehra; Konstantin Nikolaou; Gerd Grözinger
Journal:  Br J Radiol       Date:  2018-06-12       Impact factor: 3.039

2.  Endovascular treatment of pancreaticoduodenal aneurysm with braided stent-assisted coil embolization using intraoperative cone-beam computed tomography guidance.

Authors:  Marton Berczeli; Ponraj Chinnadurai; Ross G McFall; Orlando Diaz; Alan B Lumsden
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-03-31

Review 3.  Interventional Radiology in the Management of Visceral Artery Pseudoaneurysms: A Review of Techniques and Embolic Materials.

Authors:  Kumble Seetharama Madhusudhan; Hosur Ananthashayana Venkatesh; Shivanand Gamanagatti; Pramod Garg; Deep Narayan Srivastava
Journal:  Korean J Radiol       Date:  2016-04-14       Impact factor: 3.500

  3 in total