| Literature DB >> 24707108 |
Lilian Ramiro Felicio1, Cátia de Lourdes Masullo2, Marcelo Camargo Saad2, Débora Bevilaqua-Grossi2.
Abstract
A patellar bandage is often used by individuals with patellofemoral pain syndrome (PPS) to reduce pain and the additional sensorial input improves proprioception of the knee joint. The aim of this work was to assess the effect of a patellar bandage on the postural control of individuals with and without PPS.Entities:
Keywords: Patellar bandage; Patellofemoral pain syndrome; Postural control
Year: 2014 PMID: 24707108 PMCID: PMC3976027 DOI: 10.1589/jpts.26.461
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Mean and standard deviation of the anthropometric data of the PPS and Control Groups
| Characteristics | PPS Group (n=15) | Control Group (n=15) |
| Age (years) | 23.1 (2.5) | 23.2 (2.3) |
| Height (cm) | 160.5 (2.8) | 160.2 (3.3) |
| Weight (kg) | 58.7 (3.9) | 54.4 (2.1) |
| Visual Analog Pain Scale (last month) | 4.6 (1.1) | 0 |
Means and standard deviations of center of pressure variable and intragroup differences with their respective confidence intervals
| Group | Variable | Untaped Mean (SD) | CI Untaped | Taped Mean (SD) | CI Taped | Difference | CI (95%) |
| PPS | Displacement X (cm) | 5.00 (0.74) | (4.846–5.156) | 4.73 (0.65) | (4.590–4.864) | −0.27* | (−0.45–−0.09) |
| Displacement Y (cm) | 7.18 (2.09) | (6.740–7.616) | 6.99 (2.35) | (6.494–7.482) | −0.19 | (−0.74–0.36) | |
| Area of CoP (cm²) | 16.12 (4.66) | (15.144–17.10) | 14.90 (4.80) | (13.892–15.908) | −1.22* | (−2.34–−0.1) | |
| Frequency X (Hz) | 0.33 (0.31) | (0.2698–0.3998) | 0.27 (0.28) | (0.2076–0.3231) | −0.07 | (−0.14–−0.002) | |
| Frequency Y(Hz) | 0.24 (0.21) | (0.2004–0.2865) | 0.21 (0.20) | (0.1728–0.2557) | −0.03 | (−0.08–0.02) | |
| Mean speed ofdisplacement X (cm/s) | 6.68 (1.30) | (6.406–6.951) | 6.19 (1.37) | (5.902–6.476) | −0.49* | (−0.75–−0.23) | |
| Mean speed ofdisplacement Y (cm/s) | 6.22 (1.49) | (5.904–6.528) | 5.77 (1.45) | (5.464–6.073) | −0.45* | (−0.72–−0.17) | |
| Control | Displacement X (cm) | 4.90 (0.89) | (4.714–5.089) | 4.76 (0.71) | (4.616–4.914) | −0.14 | (−0.31–0.04) |
| Displacement Y (cm) | 7.39 (2.40) | (6.888–7.897) | 6.96 (1.82) | (6.576–7.34) | −0.43 | (−0.98–0.11) | |
| Area of CoP (cm²) | 16.52 (4.43) | (15.592–17.452) | 16.27 (4.36) | (15.351–17.182) | −0.25 | (−1.37–0.86) | |
| Frequency X (Hz) | 0.34 (0.24) | (0.2924–0.3952) | 0.36 (0.25) | (0.3052–0.4118) | 0.01 | (−0.05–0.08) | |
| Frequency Y(Hz) | 0.29 (0.21) | (0.242–0.3281) | 0.28 (0.18) | (0.2397–0.3158) | −0.007 | (−0.05–0.04) | |
| Mean speed ofdisplacement X (cm/s) | 5.90 (1.65) | (5.557– 6.249) | 5.80 (1.85) | (5.412–6.187) | −0.1 | (−0.36–0.16) | |
| Mean speed ofdislplacement Y (cm/s) | 5.74 (1.90) | (5.339–6.137) | 5.42 (1.99) | (5.002–5.835) | −0.32* | (−0.6–−0.04) | |
*intragroup comparison in the conditions with and without patellar bandage (p<0.05). CI: Confidence interval and SD: Standard deviation