Literature DB >> 24705955

Lab-on-paper-based devices using chemiluminescence and electrogenerated chemiluminescence detection.

Lei Ge1, Jinghua Yu, Shenguang Ge, Mei Yan.   

Abstract

As an analytical support, paper, being low cost, highly abundant, of high porosity, disposable or biodegradable, and easy to use, store, transport, and print, has excellent chemical compatibility with many applications. Since the first microfluidic paper-based analytical device (μ-PAD or lab-on-paper) was proposed, the paper-based assay has never attracted as much attention as it does now. There has recently been rapidly increasing interest in using sensitive luminescence methods, for example chemiluminescence (CL) and electrogenerated chemiluminescence (ECL), as the detection strategy for lab-on-paper devices. Because of their intrinsic characteristics, CL and ECL provide outstanding performance while retaining the simplicity, low cost, multifunctionality, versatility, flexibility, and disposability of μ-PADs. The objective of this review is to cover the development of lab-on-paper-based devices using CL and ECL detection, including fabrication of paper devices, construction of sensing interfaces, signal amplification strategies, external instruments used, and applications. We believe that lab-on-paper devices with CL and ECL detection methods will meet the diverse requirements of point-of-care diagnosis.

Mesh:

Year:  2014        PMID: 24705955     DOI: 10.1007/s00216-014-7756-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  7 in total

Review 1.  Recent Advances on Luminescent Enhancement-Based Porous Silicon Biosensors.

Authors:  S N Aisyiyah Jenie; Sally E Plush; Nicolas H Voelcker
Journal:  Pharm Res       Date:  2016-02-25       Impact factor: 4.200

2.  Paper-based chemiluminescence immunodevice for the carcinoembryonic antigen by employing multi-enzyme carbon nanosphere signal enhancement.

Authors:  Ying Chen; Weiru Chu; Wei Liu; Xiaoyan Guo; Yan Jin; Baoxin Li
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

3.  Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip).

Authors:  Meili Dong; Jiandong Wu; Zimin Ma; Hagit Peretz-Soroka; Michael Zhang; Paul Komenda; Navdeep Tangri; Yong Liu; Claudio Rigatto; Francis Lin
Journal:  Sensors (Basel)       Date:  2017-03-26       Impact factor: 3.576

4.  A single-electrode electrochemical system for multiplex electrochemiluminescence analysis based on a resistance induced potential difference.

Authors:  Wenyue Gao; Kateryna Muzyka; Xiangui Ma; Baohua Lou; Guobao Xu
Journal:  Chem Sci       Date:  2018-03-19       Impact factor: 9.825

5.  Smartphone-Based Chemiluminescent Origami µPAD for the Rapid Assessment of Glucose Blood Levels.

Authors:  Donato Calabria; Martina Zangheri; Ilaria Trozzi; Elisa Lazzarini; Andrea Pace; Mara Mirasoli; Massimo Guardigli
Journal:  Biosensors (Basel)       Date:  2021-10-09

Review 6.  Point-of-Care Diagnostics for Farm Animal Diseases: From Biosensors to Integrated Lab-on-Chip Devices.

Authors:  Georgios Manessis; Athanasios I Gelasakis; Ioannis Bossis
Journal:  Biosensors (Basel)       Date:  2022-06-26

7.  [Applications of microfluidic paper-based chips in environmental analysis and detection].

Authors:  Yu Zhang; Ji Qi; Feng Liu; Ning Wang; Xiyan Sun; Rong Cui; Jialuo Yu; Jiaming Ye; Ping Liu; Bowei Li; Lingxin Chen
Journal:  Se Pu       Date:  2021-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.