Literature DB >> 24704648

Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR.

Sang-Sub Park1.   

Abstract

The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).

Entities:  

Keywords:  Cardiopulmonary resuscitation; application; chest compression; smartphone

Mesh:

Year:  2014        PMID: 24704648     DOI: 10.3233/THC-140791

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  4 in total

1.  Effect of smartphone applications on cardiopulmonary resuscitation quality metrics in a mannequin study: A randomized trial.

Authors:  Hüseyin Sevil; Volga Bastan; Esma Gültürk; Imad El Majzoub; Erkan Göksu
Journal:  Turk J Emerg Med       Date:  2021-04-09

Review 2.  [Basic life support].

Authors:  Theresa M Olasveengen; Federico Semeraro; Giuseppe Ristagno; Maaret Castren; Anthony Handley; Artem Kuzovlev; Koenraad G Monsieurs; Violetta Raffay; Michael Smyth; Jasmeet Soar; Hildigunnur Svavarsdóttir; Gavin D Perkins
Journal:  Notf Rett Med       Date:  2021-06-02       Impact factor: 0.826

3.  Impact of a Smart-Ring-Based Feedback System on the Quality of Chest Compressions in Adult Cardiac Arrest: A Randomized Preliminary Study.

Authors:  Chiwon Ahn; Seungjae Lee; Jongshill Lee; Jaehoon Oh; Yeongtak Song; In Young Kim; Hyunggoo Kang
Journal:  Int J Environ Res Public Health       Date:  2021-05-19       Impact factor: 3.390

4.  Effectiveness of Mobile Health Application Use to Improve Health Behavior Changes: A Systematic Review of Randomized Controlled Trials.

Authors:  Myeunghee Han; Eunjoo Lee
Journal:  Healthc Inform Res       Date:  2018-07-31
  4 in total