Literature DB >> 24704631

Semi-automatic border detection software for the quantification of arterial lumen, intima-media and adventitia layer thickness with very-high resolution ultrasound.

Johnny Sundholm1, Tomas Gustavsson2, Taisto Sarkola3.   

Abstract

BACKGROUND: The aim was to evaluate the accuracy, precision and feasibility of semi-automatic border detection software (AMS) in comparison to manual electronic calipers (EC) in the analysis of arterial images obtained with transcutaneous very-high resolution vascular ultrasound (VHRU, 25-55 MHz).
METHODS: 100 images from central elastic and peripheral muscular arteries were obtained on two separate imaging occasions from 10 healthy subjects, and independently measured with AMS and EC.
RESULTS: No bias between AMS and EC was found. The intraobserver coefficients of variation (CV) for carotid lumen dimension (mean dimension 5.60 mm) was lower with AMS compared with EC (0.4 vs. 1.9%, p = 0.033; N = 20). No consistently significant differences in intra, inter or test-retest CVs were observed overall for muscular artery dimensions between AMS and EC. The intra CV for adventitial thickness (AT, mean 0.111 mm; 15.6 vs 24.8%, p = 0.011; N = 41) and inter CV for intima-media thickness (IMT, mean 0.219 mm; 14.3 vs. 21.2%, p = 0.001; N = 58) obtained with AMS in higher quality thin muscular artery images was lower compared with EC. The mean reading time was significantly lower with AMS compared with EC (71.5 s vs. 156.6 s, p < 0.001).
CONCLUSION: AMS is accurate, precise, and feasible in the analysis of arterial images obtained with VHRU. Minor, although statistically significant, differences in the precision of AMS and EC-systems were found. The precision of AMS was superior for AT and IMT in higher quality images likely related to a decrease in the technical variability imposed by the observer.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Adventitia; Border detection software; Intima-media; Very-high resolution ultrasound

Mesh:

Year:  2014        PMID: 24704631     DOI: 10.1016/j.atherosclerosis.2014.03.006

Source DB:  PubMed          Journal:  Atherosclerosis        ISSN: 0021-9150            Impact factor:   5.162


  3 in total

1.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

2.  Detection of subclinical atherosclerosis in asymptomatic subjects using ultrasound radiofrequency-tracking technology.

Authors:  Lili Niu; Yanling Zhang; Long Meng; Yang Xiao; Kelvin K L Wong; Derek Abbott; Hairong Zheng; Rongqin Zheng; Ming Qian
Journal:  PLoS One       Date:  2014-11-04       Impact factor: 3.240

3.  Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements.

Authors:  Kate McCloskey; Anne-Louise Ponsonby; John B Carlin; Kim Jachno; Michael Cheung; Michael R Skilton; Jane Koleff; Peter Vuillermin; David Burgner
Journal:  Cardiovasc Ultrasound       Date:  2014-06-03       Impact factor: 2.062

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.