In-vivo 6 degrees-of-freedom kinematics of metal-on-polyethylene total hip arthroplasty during gait.

Tsung-Yuan Tsai1, Jing-Sheng Li1, Shaobai Wang1, Donna Scarborough1, Young-Min Kwon2.   

Abstract

Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with respect to the underlying bones. A non-invasive dual fluoroscopic imaging system (DFIS) based tracking technique has been used to avoid skin artifacts and provide accurate 6-DOF kinematic measurement. This study aimed to quantify in-vivo 6-DOF THA kinematics during gait using DFIS. Twenty eight well-functioning THAs were evaluated during treadmill gait under DFIS surveillance. The maximum translations of the femoral head were 0.46±0.10mm and 0.45±0.10mm during the stance and swing phases (p=0.57), respectively. The range of hip flexion was from 8.7° to 47.6°, adduction from 3.0° to 12.5° and external rotation from 19.2° to 29.7°. The THA was flexed, externally rotated and adducted throughout the gait. The magnitudes of the femoral head translations were found to be within the manufacture tolerance of the components, suggesting that in-vivo hip "pistoning" during gait cycle may be minimal in well-functioning THAs. The 6-DOF kinematics could be used as the baseline knowledge for further improvement of wear-testing of hip implant, implants manufacturing and implant positioning during surgery.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fluoroscope; Gait; Kinematics; Total hip arthroplasty; in vivo

Mesh:

Substances:

Year:  2014        PMID: 24704170     DOI: 10.1016/j.jbiomech.2014.03.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling.

Authors:  Fabio D'Isidoro; Christophe Chênes; Stephen J Ferguson; Jérôme Schmid
Journal:  Med Phys       Date:  2021-08-17       Impact factor: 4.506

2.  Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty.

Authors:  Xiangjun Hu; Nan Zheng; Yunsu Chen; Kerong Dai; Dimitris Dimitriou; Huiwu Li; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2021-03-30

3.  Does treadmill workstation use affect user's kinematic gait symmetry?

Authors:  Paul Gonzalo Arauz; María-Gabriela García; Mauricio Velez; Cesar León; Francisco Velez; Bernard Martin
Journal:  PLoS One       Date:  2021-12-14       Impact factor: 3.240

4.  Postoperative Hip Center Position Associated With the Range of Internal Rotation and Extension During Gait in Hip Dysplasia Patients After Total Hip Arthroplasty.

Authors:  Yi Hu; Diyang Zou; Qi Sun; Mengda Jiang; Huiwu Li; Tsung-Yuan Tsai; Jingwei Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.