Cementless RM Pressfit Cup: a clinical and radiological study of 91 cases with at least four years follow-up.

L Lafon1, H Moubarak1, J Druon1, P Rosset2.   

Abstract

UNLABELLED: Cementless metal-back acetabular cups have good long-term results, but some problems have appeared due to the shell's stiffness, modularity and required bearing surfaces. The RM Pressfit Cup is a single-piece polyethylene cementless acetabular cup that is covered by a thin layer of titanium. This allows for bone integration without limitations related to the stiffness of a metal-back shell. There is very little published information about this new, innovative implant design. The purpose of this study was to evaluate the clinical and radiological results from a continuous series of 91 cups (85 patients) with a follow-up of at least 4 years. No patients were lost to follow-up. The Harris Hip Score (HHS) was used to assess the clinical outcome. To assess the radiological outcomes, digital X-rays were used to evaluate the cup position and integration; wear was measured using Livermore's technique. The clinical results were excellent: the mean HHS was 94 and 82% of cases had good or excellent scores. Three of the cups had to be revised because of dislocation brought on by incorrect positioning. X-rays revealed that three implants had shifted during the first 6 weeks, but had stabilized afterwards. Bone integration on X-rays was satisfactory in all cases with no signs of osteolysis. The configuration of the bone trabeculae showed that loads between the implant and peri-acetabular cancellous bone were evenly distributed. The wear of the polyethylene cup-ceramic head bearing was 0.07 mm/year. The results of this series are consistent with recent published studies with the RM Pressfit Cup. LEVEL OF EVIDENCE: IV.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Cementless acetabular cup; Osseointegration; Total hip arthroplasty

Mesh:

Substances:

Year:  2014        PMID: 24703794     DOI: 10.1016/j.otsr.2014.03.007

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  3 in total

1.  Does a titanium-coated polyethylene press-fit cup give reliable midterm results?

Authors:  Nikki Hooper; Harry Sargeant; Chris Frampton; Gary Hooper
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

3.  Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study.

Authors:  Conrad Anderl; Georg Mattiassich; Reinhold Ortmaier; Martin Steinmair; Josef Hochreiter
Journal:  BMC Musculoskelet Disord       Date:  2020-10-06       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.