Temperature-dependent polymerization shrinkage stress kinetics of resin-composites.

D C Watts1, A Alnazzawi2.   

Abstract

OBJECTIVES: To determine temperature dependence of shrinkage stress kinetics for a set of resin composites formulated with dimethacrylate monomer matrices.
METHODS: Six representative resin composites with a range of resin matrices were selected. Two of them were considered as low shrinking resin composites: Kalore and Venus Diamond. The shrinkage stress kinetics at 23°C and 37°C were measured continuously using a Bioman instrument for 60min. Stress levels between materials were compared at two intervals: 2min and 60min. Specimen temperatures were controlled by a newly designed heating device. Stress measurements were monitored for 1h, after irradiation for 40s at 550mW/cm(2) (energy density=22J/cm(2)). Three specimens (n=3) were used at each temperature per material.
RESULTS: Shrinkage stress at 23°C ranged from 2.93MPa to 4.71MPa and from 3.57MPa to 5.42MPa for 2min and 60min after photo-activation, respectively. The lowest stress-rates were recorded for Kalore and Venus Diamond (0.34MPas(-1)), whereas the highest was recorded for Filtek Supreme XTE (0.63MPas(-1)). At 37°C, shrinkage stress ranged from 3.27MPa to 5.35MPa and from 3.36MPa to 5.49MPa for 2min and 60min after photo-activation, respectively. Kalore had the lowest stress-rate (0.44MPas(-1)), whereas Filtek Supreme XTE had the highest (0.85MPas(-1)). Materials exhibited a higher stress at 37°C than 23°C except for Kalore and Venus Diamond. Positive correlations were found between shrinkage stress and stress-rate at 23°C and 37°C (r=0.70 and 0.92, respectively). SIGNIFICANCE: Resin-composites polymerized at elevated temperature (37°C) completed stress build up more rapidly than specimens held at 23°C. Two composites exhibited atypical reduced stress magnitudes at the higher temperature.
Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Polymerization; Resin composite; Shrinkage; Stress; Temperature

Mesh:

Substances:

Year:  2014        PMID: 24703546     DOI: 10.1016/j.dental.2014.03.004

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Development of a multifunctional adhesive system for prevention of root caries and secondary caries.

Authors:  Ning Zhang; Mary A S Melo; Chen Chen; Jason Liu; Michael D Weir; Yuxing Bai; Hockin H K Xu
Journal:  Dent Mater       Date:  2015-07-14       Impact factor: 5.304

2.  Polymerization stress evolution of a bulk-fill flowable composite under different compliances.

Authors:  Yongwen Guo; Forrest A Landis; Zhengzhi Wang; Ding Bai; Li Jiang; Martin Y M Chiang
Journal:  Dent Mater       Date:  2016-02-06       Impact factor: 5.304

3.  Dimensional stability of short fibre reinforced flowable dental composites.

Authors:  Raju Raju; Ginu Rajan; Paul Farrar; B Gangadhara Prusty
Journal:  Sci Rep       Date:  2021-02-25       Impact factor: 4.379

4.  Effects of water-aging for 6 months on the durability of a novel antimicrobial and protein-repellent dental bonding agent.

Authors:  Ning Zhang; Ke Zhang; Michael D Weir; David J Xu; Mark A Reynolds; Yuxing Bai; Hockin H K Xu
Journal:  Int J Oral Sci       Date:  2018-06-21       Impact factor: 6.344

5.  Hot Lithography Vat Photopolymerisation 3D Printing: Vat Temperature vs. Mixture Design.

Authors:  Farzaneh Sameni; Basar Ozkan; Hanifeh Zarezadeh; Sarah Karmel; Daniel S Engstrøm; Ehsan Sabet
Journal:  Polymers (Basel)       Date:  2022-07-23       Impact factor: 4.967

6.  Effect of a novel commercial potassium-oxalate containing tooth-desensitizing mouthrinse on the microhardness of resin composite restorative materials with different monomer compositions.

Authors:  Barış Karabulut; Deniz C Can-Karabulut; Serkan Güleç; Cem M Doğan
Journal:  J Clin Exp Dent       Date:  2016-12-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.