Optimizing centrifugation of coagulation samples in laboratory automation.

Juliane Suchsland, Nele Friedrich, Anne Grotevendt, Anders Kallner, Jan Lüdemann, Matthias Nauck, Astrid Petersmann.   

Abstract

BACKGROUND: High acceleration centrifugation conditions are used in laboratory automation systems to reduce the turnaround time (TAT) of clinical chemistry samples, but not of coagulation samples. This often requires separate sample flows. The CLSI guideline and manufacturers recommendations for coagulation assays aim at reducing platelet counts. For measurement of prothrombin time (PT) and activated partial thromboplastin time (APTT) platelet counts (Plt) below 200×10(9)/L are recommended. Other coagulation assays may require even lower platelet counts, e.g., less than 10 × 10(9)/L. Unifying centrifugation conditions can facilitate the integration of coagulation samples in the overall workflow of a laboratory automation system.
METHODS: We evaluated centrifugation conditions of coagulation samples by using high acceleration centrifugation conditions (5 min; 3280×g) in a single and two consecutive runs. RESULTS of coagulation assays [PT, APTT, coagulation factor VIII (F. VIII) and protein S] and platelet counts were compared after the first and second centrifugation.
RESULTS: Platelet counts below 200×10(9)/L were obtained in all samples after the first centrifugation and less than 10 × 10(9)/L was obtained in 73% of the samples after a second centrifugation. Passing-Bablok regression analyses showed an equal performance of PT, APTT and F. VIII after first and second centrifugation whereas protein S measurements require a second centrifugation.
CONCLUSIONS: Coagulation samples can be integrated into the workflow of a laboratory automation system using high acceleration centrifugation. A single centrifugation was sufficient for PT, APTT and F. VIII whereas two successive centrifugations appear to be sufficient for protein S activity.

Entities:  

Mesh:

Year:  2014        PMID: 24695042     DOI: 10.1515/cclm-2014-0038

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Does centrifugation matter? Centrifugal force and spinning time alter the plasma metabolome.

Authors:  Dorothea Lesche; Roland Geyer; Daniel Lienhard; Christos T Nakas; Gaëlle Diserens; Peter Vermathen; Alexander B Leichtle
Journal:  Metabolomics       Date:  2016-09-15       Impact factor: 4.290

Review 2.  Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

Authors:  A Magnette; M Chatelain; B Chatelain; H Ten Cate; F Mullier
Journal:  Thromb J       Date:  2016-12-12

3.  Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

Authors:  Janne Cadamuro; Cornelia Mrazek; Alexander B Leichtle; Ulrike Kipman; Thomas K Felder; Helmut Wiedemann; Hannes Oberkofler; Georg M Fiedler; Elisabeth Haschke-Becher
Journal:  Biochem Med (Zagreb)       Date:  2017-11-24       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.