Literature DB >> 24694152

Three-dimensional liver motion tracking using real-time two-dimensional MRI.

Lau Brix1, Steffen Ringgaard2, Thomas Sangild Sørensen3, Per Rugaard Poulsen4.   

Abstract

PURPOSE: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution.
METHODS: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions.
RESULTS: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane).
CONCLUSIONS: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.
© 2014 American Association of Physicists in Medicine.

Entities:  

Mesh:

Year:  2014        PMID: 24694152     DOI: 10.1118/1.4867859

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Spatiotemporal fractionation schemes for liver stereotactic body radiotherapy.

Authors:  Jan Unkelbach; Dávid Papp; Melissa R Gaddy; Nicolaus Andratschke; Theodore Hong; Matthias Guckenberger
Journal:  Radiother Oncol       Date:  2017-09-23       Impact factor: 6.280

2.  A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

Authors:  Chiara Paganelli; Paul Summers; Chiara Gianoli; Massimo Bellomi; Guido Baroni; Marco Riboldi
Journal:  Med Biol Eng Comput       Date:  2017-04-08       Impact factor: 2.602

Review 3.  The future of image-guided radiotherapy will be MR guided.

Authors:  Julianne M Pollard; Zhifei Wen; Ramaswamy Sadagopan; Jihong Wang; Geoffrey S Ibbott
Journal:  Br J Radiol       Date:  2017-03-29       Impact factor: 3.039

4.  Pancreas deformation in the presence of tumors using feature tracking from free-breathing XD-GRASP MRI.

Authors:  Teodora Chitiboi; Matthew Muckley; Bari Dane; Chenchan Huang; Li Feng; Hersh Chandarana
Journal:  J Magn Reson Imaging       Date:  2019-03-10       Impact factor: 4.813

5.  A fast volumetric 4D-MRI with sub-second frame rate for abdominal motion monitoring and characterization in MRI-guided radiotherapy.

Authors:  Jing Yuan; Oi Lei Wong; Yihang Zhou; Kin Yin Chueng; Siu Ki Yu
Journal:  Quant Imaging Med Surg       Date:  2019-07

6.  Investigation of dosimetric variations of liver radiotherapy using deformable registration of planning CT and cone-beam CT.

Authors:  Pu Huang; Gang Yu; Jinhu Chen; Changsheng Ma; Shaohua Qin; Yong Yin; Yueqiang Liang; Hongsheng Li; Dengwang Li
Journal:  J Appl Clin Med Phys       Date:  2016-12-05       Impact factor: 2.102

7.  Radiotherapy planning using MRI.

Authors:  Maria A Schmidt; Geoffrey S Payne
Journal:  Phys Med Biol       Date:  2015-10-28       Impact factor: 3.609

8.  Observation of different tumor motion magnitude within liver and estimate of internal motion margins in postoperative patients with hepatocellular carcinoma.

Authors:  Yu-Ting Zhao; Zhi-Kai Liu; Qiu-Wen Wu; Jian-Rong Dai; Tao Zhang; Angela Y Jia; Jing Jin; Shu-Lian Wang; Ye-Xiong Li; Wei-Hu Wang
Journal:  Cancer Manag Res       Date:  2017-12-12       Impact factor: 3.989

9.  Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study.

Authors:  Martin F Fast; Björn Eiben; Martin J Menten; Andreas Wetscherek; David J Hawkes; Jamie R McClelland; Uwe Oelfke
Journal:  Radiother Oncol       Date:  2017-10-10       Impact factor: 6.280

Review 10.  Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review.

Authors:  S A Yoganathan; K J Maria Das; Arpita Agarwal; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Jul-Sep
View more