Abstract

MRI and MRS in small rodents demand very high sensitivity. Cryogenic transmit/receive radiofrequency probes (CryoProbes) designed for (1) H MRI of mouse brain provide an attractive option for increasing the performance of small-animal MR systems. As the Larmor frequency of (13) C nuclei is four times lower than that for (1) H nuclei, an even larger sensitivity improvement is expected for (13) C applications. The aim of this work was to evaluate the performance of a prototype (13) C CryoProbe™ for mouse brain MRS. To investigate the possible gain of the (13) C CryoProbe™, we acquired localized single-voxel (13) C spectra and chemical shift images of a dimethyl sulfoxide phantom with the CryoProbe™, as well as with two room temperature resonators. The cryogenically cooled resonator achieved approximately four-fold higher signal-to-noise ratio in phantom tests when compared with the best-performing room temperature coil. In addition, we present localized (13) C spectra of mouse brain obtained with the CryoProbe™, as well as with one of the room temperature coils, demonstrating the performance in vivo. In summary, the cryogenic cooling technique significantly enhances the (13) C signal sensitivity at 9.4 T and enables the investigation of metabolism within mouse brain.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  13C spectroscopy; CryoProbe™; MRS; SNR comparison; cryogenic coil; mouse

Mesh:

Substances:

Year:  2014        PMID: 24692120     DOI: 10.1002/nbm.3110

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  9 in total

1.  Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.

Authors:  Paula Ramos Delgado; Ekkehard Küstermann; André Kühne; Jason M Millward; Thoralf Niendorf; Andreas Pohlmann; Martin Meier
Journal:  Methods Mol Biol       Date:  2021

Review 2.  The use of hyperpolarized carbon-13 magnetic resonance for molecular imaging.

Authors:  Sarmad Siddiqui; Stephen Kadlecek; Mehrdad Pourfathi; Yi Xin; William Mannherz; Hooman Hamedani; Nicholas Drachman; Kai Ruppert; Justin Clapp; Rahim Rizi
Journal:  Adv Drug Deliv Rev       Date:  2016-09-04       Impact factor: 15.470

3.  On the magnetic field dependence of deuterium metabolic imaging.

Authors:  Robin A de Graaf; Arjan D Hendriks; Dennis W J Klomp; Chathura Kumaragamage; Dimitri Welting; Catalina S Arteaga de Castro; Peter B Brown; Scott McIntyre; Terence W Nixon; Jeanine J Prompers; Henk M De Feyter
Journal:  NMR Biomed       Date:  2019-12-26       Impact factor: 4.044

4.  Functional Imaging Using Fluorine (19F) MR Methods: Basic Concepts.

Authors:  Sonia Waiczies; Christian Prinz; Ludger Starke; Jason M Millward; Paula Ramos Delgado; Jens Rosenberg; Marc Nazaré; Helmar Waiczies; Andreas Pohlmann; Thoralf Niendorf
Journal:  Methods Mol Biol       Date:  2021

5.  Spatially Localized Two-Dimensional J-Resolved NMR Spectroscopy via Intermolecular Double-Quantum Coherences for Biological Samples at 7 T.

Authors:  Chunhua Tan; Shuhui Cai; Yuqing Huang
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

6.  Strategies for the hyperpolarization of acetonitrile and related ligands by SABRE.

Authors:  Ryan E Mewis; Richard A Green; Martin C R Cockett; Michael J Cowley; Simon B Duckett; Gary G R Green; Richard O John; Peter J Rayner; David C Williamson
Journal:  J Phys Chem B       Date:  2015-01-13       Impact factor: 2.991

7.  A polymer-based magnetic resonance tracer for visualization of solid tumors by 13C spectroscopic imaging.

Authors:  Yoshikazu Suzuki; Mitsuru Iida; Iwao Miura; Toshiro Inubushi; Shigehiro Morikawa
Journal:  PLoS One       Date:  2014-07-09       Impact factor: 3.240

Review 8.  Advancing Cardiovascular, Neurovascular, and Renal Magnetic Resonance Imaging in Small Rodents Using Cryogenic Radiofrequency Coil Technology.

Authors:  Thoralf Niendorf; Andreas Pohlmann; Henning M Reimann; Helmar Waiczies; Eva Peper; Till Huelnhagen; Erdmann Seeliger; Adrian Schreiber; Ralph Kettritz; Klaus Strobel; Min-Chi Ku; Sonia Waiczies
Journal:  Front Pharmacol       Date:  2015-11-12       Impact factor: 5.810

Review 9.  Parahydrogen-Induced Polarization of Amino Acids.

Authors:  Andrey N Pravdivtsev; Gerd Buntkowsky; Simon B Duckett; Igor V Koptyug; Jan-Bernd Hövener
Journal:  Angew Chem Int Ed Engl       Date:  2021-08-13       Impact factor: 15.336

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.