Literature DB >> 24690449

Comparison and analysis of three different methods to evaluate vertical jump height.

Hung Tien Bui1, Marie-Isabelle Farinas, Anne-Marie Fortin, Alain-Steve Comtois, Mario Leone.   

Abstract

The purpose of this study was to compare three methods to assess vertical jump height, to determine their limitations and to propose solutions to mitigate their effects. The chosen methods were the contact mat, the optical system and the Sargent jump. The testing environment was designed such that all three systems simultaneously measured the vertical jump height. A total of 41 kinesiology students (18 women, 23 men, mean age 23·2 ± 4·5 years) participated in this study. Data show that the contact mat and the optical system essentially provide similar results (P = 0·912) and that the correlation coefficient between the two systems was 0·972 (r(2)  = 0·944). However, it was found that the Sargent jump has a tendency to overestimate the height, providing a measurement that is significantly different from the other two methods as the jumps are higher than 30·64 cm (P = 0·044). Through the design of the experiment, several sources of errors were identified and mathematically modelled. These sources include optical sensor placement, flat-footed landing and hip/knee bend. Whenever possible, the errors were quantified and solutions were proposed.
© 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Sargent jump; contact mat; lower limb power; optical sensor; reliability

Mesh:

Year:  2014        PMID: 24690449     DOI: 10.1111/cpf.12148

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  4 in total

1.  Validity and reliability of the WIMU inertial device for the assessment of the vertical jump.

Authors:  José Pino-Ortega; Javier García-Rubio; Sergio J Ibáñez
Journal:  PeerJ       Date:  2018-04-30       Impact factor: 2.984

2.  Muscle fitness and its association with body mass index in children and adolescents aged 7-18 years in China: a cross-sectional study.

Authors:  Huijing He; Li Pan; Jianwei Du; Feng Liu; Yuming Jin; Jingang Ma; Li Wang; Pengben Jia; Zhiping Hu; Guangliang Shan
Journal:  BMC Pediatr       Date:  2019-04-10       Impact factor: 2.125

3.  Force-Sensitive Mat for Vertical Jump Measurement to Assess Lower Limb Strength: Validity and Reliability Study.

Authors:  Erik Vanegas; Yolocuauhtli Salazar; Raúl Igual; Inmaculada Plaza
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-09       Impact factor: 4.773

Review 4.  A Review of Countermovement and Squat Jump Testing Methods in the Context of Public Health Examination in Adolescence: Reliability and Feasibility of Current Testing Procedures.

Authors:  Luca Petrigna; Bettina Karsten; Giuseppe Marcolin; Antonio Paoli; Giuseppe D'Antona; Antonio Palma; Antonino Bianco
Journal:  Front Physiol       Date:  2019-11-07       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.