Literature DB >> 24689838

Treatment of refractory open-angle glaucoma using ultrasonic circular cyclocoagulation: a prospective case series.

Florent Aptel1, Caroline Dupuy, Jean-François Rouland.   

Abstract

OBJECTIVE: To evaluate the efficacy and safety of the ultrasonic circular cyclocoagulation (UC(3)) procedure in patients with refractory primary open-angle glaucoma. RESEARCH DESIGN AND METHODS: Prospective non-comparative interventional case series performed in two French glaucoma centers. Twenty-eight eyes of 28 patients with primary open-angle glaucoma, intraocular pressure (IOP) >21 mmHg, an average of 1.4 failed previous surgeries and an average of 3.8 hypotensive medications were insonified with a therapy probe comprising six piezoelectric transducers. The six transducers were activated and all patients were treated with a 6 second exposure time. Complete ophthalmic examinations were performed before the procedure, and at 1 day, 1 week, 1, 2, 3, 6 and 12 months after. MAIN OUTCOME MEASURES: Primary outcomes were surgical success (defined as IOP reduction from baseline ≥20% and IOP >5 mmHg) at the last follow-up visit, and vision-threatening complications. Secondary outcomes were mean IOP at each follow-up visit compared to baseline, medication use, complications, and re-interventions.
RESULTS: IOP was significantly reduced (P < 0.05), from a mean preoperative value of 29.0 ± 7.2 mmHg (n = 3.8 hypotensive medications) to a mean value of 21.6 ± 9.4 mmHg at last follow-up (n = 3.8 hypotensive medications and n = 1.29 procedures) (mean IOP reduction of 26%). Complete success (IOP reduction >20% without re-intervention and without hypotensive medications adjunction) was achieved in 50% of eyes at last follow-up (mean IOP reduction of 45% in these same eyes) and qualified success (IOP reduction >20% with possible re-interventions) was achieved in 68% of eyes at last follow-up. No major intra- or post-operative complications occurred.
CONCLUSIONS: UC(3) procedure seems to be an effective and well tolerated method to reduce intraocular pressure in patients with primary open-angle glaucoma. Studies directly comparing the efficacy and safety of the UC(3) procedure with that of trabeculectomy or diode laser are needed.

Entities:  

Keywords:  Ciliary body; Glaucoma; Intraocular pressure; Ultrasound

Mesh:

Year:  2014        PMID: 24689838     DOI: 10.1185/03007995.2014.910509

Source DB:  PubMed          Journal:  Curr Med Res Opin        ISSN: 0300-7995            Impact factor:   2.580


  13 in total

1.  Safety and efficacy of multiple cyclocoagulation of ciliary bodies by high-intensity focused ultrasound in patients with glaucoma.

Authors:  Alessandra De Gregorio; Emilio Pedrotti; Giulia Stevan; Margherita Montali; Simonetta Morselli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-10-17       Impact factor: 3.117

2.  Ultrasound Cyclo Plasty in Eyes with Glaucoma.

Authors:  Giuseppe Giannaccare; Stefano Sebastiani; Emilio C Campos
Journal:  J Vis Exp       Date:  2018-01-26       Impact factor: 1.355

3.  High-intensity focused ultrasound treatment in patients with refractory glaucoma.

Authors:  Giuseppe Giannaccare; A Vagge; C Gizzi; A Bagnis; S Sebastiani; C Del Noce; M Fresina; C E Traverso; E C Campos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-12-03       Impact factor: 3.117

Review 4.  Evolution of Cyclophotocoagulation.

Authors:  Jideofor K Ndulue; Kamran Rahmatnejad; Carina Sanvicente; Sheryl S Wizov; Marlene R Moster
Journal:  J Ophthalmic Vis Res       Date:  2018 Jan-Mar

Review 5.  Cyclodestructive Procedures in Glaucoma: A Review of Current and Emerging Options.

Authors:  Anna I Dastiridou; Andreas Katsanos; Philippe Denis; Brian A Francis; Dimitrios G Mikropoulos; Miguel A Teus; Anastasios-Georgios Konstas
Journal:  Adv Ther       Date:  2018-11-17       Impact factor: 3.845

6.  Short-Term Observation of Ultrasonic Cyclocoagulation in Chinese Patients with End-Stage Refractory Glaucoma: A Retrospective Study.

Authors:  Dongpeng Hu; Shu Tu; Chengguo Zuo; Jian Ge
Journal:  J Ophthalmol       Date:  2018-09-06       Impact factor: 1.909

Review 7.  High-Intensity Focused Ultrasound Circular Cyclocoagulation in Glaucoma: A Step Forward for Cyclodestruction?

Authors:  Rodolfo Mastropasqua; Vincenzo Fasanella; Alessandra Mastropasqua; Marco Ciancaglini; Luca Agnifili
Journal:  J Ophthalmol       Date:  2017-04-22       Impact factor: 1.909

8.  Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients.

Authors:  Nilanjana Deb-Joardar; Kasu Prasad Reddy
Journal:  Indian J Ophthalmol       Date:  2018-04       Impact factor: 1.848

9.  High intensity focused ultrasound cyclocoagulation in dogs with primary glaucoma: a preliminary study.

Authors:  Pierre-François Isard; Marielle Mentek; David Clément; Aurélie Béglé; Fabrice Romano; Florent Aptel; Iona Mathieson; Thomas Dulaurent
Journal:  Open Vet J       Date:  2018-08-13

10.  Efficacy and safety of ultrasonic circular cyclocoagulation with second-generation probe in glaucoma: A retrospective study.

Authors:  Chloé Chamard; Vincent Daien; Hyosun Han; David S Greenfield; Max Villain
Journal:  PLoS One       Date:  2020-01-24       Impact factor: 3.240

View more