Literature DB >> 24689727

Accuracy of conventional transthoracic echocardiography for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies.

Mohammad Khalid Mojadidi1, Jared S Winoker, Scott C Roberts, Pavlos Msaouel, Muhammad Omer Zaman, Rubine Gevorgyan, Jonathan M Tobis.   

Abstract

BACKGROUND: Paradoxical embolization through a right-to-left shunt (RLS), often from a patent foramen ovale (PFO), has been associated with cryptogenic stroke. While transesophageal echo (TEE) bubble study is the current standard reference for diagnosing PFO, transthoracic echo (TTE) remains the most commonly used screening test for RLS due to its noninvasiveness and easy availability. The aim of this meta-analysis was to determine the accuracy of TTE compared to TEE as the reference. METHODS AND
RESULTS: A systematic review of Medline, Cochrane, and Embase was done to look for all the prospective studies assessing for intracardiac RLS using conventional TTE compared to TEE as the reference; both TTE and TEE were performed with a contrast agent and a maneuver to provoke RLS in all studies. A total of 13 studies with 1436 patients fulfilled the inclusion criteria. The weighted mean sensitivity and specificity for TTE were 46% and 99%, respectively. Likewise, the positive likelihood ratio and negative likelihood ratio were 20.85 and 0.57, respectively. Using different contrast agents, different microbubble cutoffs for a positive TTE/TEE, and different cardiac cycle cutoffs for a positive TTE/TEE did not affect the accuracy of TTE. In a population of patients with cryptogenic stroke, a TTE that tests positive for RLS has a 95% probability of being a true positive.
CONCLUSION: Transthoracic echocardiogram has a low sensitivity and extremely high specificity, making it a poor rule out test but an excellent rule in test for the detection of intracardiac RLS.
© 2014, Wiley Periodicals, Inc.

Entities:  

Keywords:  patent foramen ovale; right-to-left shunt; transesophageal echocardiogram; transthoracic echocardiogram

Mesh:

Year:  2014        PMID: 24689727     DOI: 10.1111/echo.12583

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  14 in total

1.  Comparison of Figulla Flex® and Amplatzer™ devices for atrial septal defect closure: A meta-analysis.

Authors:  Alvaro Aparisi; Roman J Arnold; Hipólito Gutiérrez; Ana Revilla; Ana Serrador; Benigno Ramos; Tania Rodriguez-Gabella; Alberto Campo; Carlos Baladrón; Itziar Gómez; Manuel Carrasco-Moraleja; José A San Roman; Ignacio J Amat-Santos
Journal:  Cardiol J       Date:  2020-04-24       Impact factor: 2.737

2.  Sleep Apnea in Patients with and without a Right-to-Left Shunt.

Authors:  Mohammad Khalid Mojadidi; Pooya Isaac Bokhoor; Rubine Gevorgyan; Nabil Noureddin; W Cameron MacLellan; Eugenia Wen; Ravi Aysola; Jonathan M Tobis
Journal:  J Clin Sleep Med       Date:  2015-11-15       Impact factor: 4.062

Review 3.  The management of patent foramen ovale in divers: where do we stand?

Authors:  Anastasios Apostolos; Maria Drakopoulou; George Trantalis; Αndreas Synetos; George Oikonomou; Theodoros Karapanayiotides; Costas Tsioufis; Konstantinos Toutouzas
Journal:  Ther Adv Neurol Disord       Date:  2022-07-09       Impact factor: 6.430

4.  Stepwise Progression of Right-to-Left Atrial Shunting through a Combination of Patent Foramen Ovale and Tricuspid Regurgitation.

Authors:  Evan P Kransdorf; Lisa N Kransdorf; F David Fortuin; John P Sweeney; Susan Wilansky
Journal:  Tex Heart Inst J       Date:  2016-04-01

5.  Two-dimensional echocardiography using second harmonic imaging for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies.

Authors:  Mohammad Khalid Mojadidi; Jared S Winoker; Scott C Roberts; Pavlos Msaouel; Rubine Gevorgyan; Ronald Zolty
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-17       Impact factor: 2.357

6.  Persistent iatrogenic atrial septal defects after pulmonary vein isolation: long-term follow-up with contrast transesophageal echocardiography.

Authors:  Allan Davies; Prasad Gunaruwan; Nicholas Collins; Malcolm Barlow; Nick Jackson; James Leitch
Journal:  J Interv Card Electrophysiol       Date:  2016-09-28       Impact factor: 1.900

7.  Value of routine echocardiography in the management of stroke.

Authors:  Mike Fralick; Nicola Goldberg; Sagar Rohailla; Yishan Guo; Matthew J Burke; Lauren Lapointe-Shaw; Janice L Kwan; Adina S Weinerman; Shail Rawal; Terence Tang; Fahad Razak; Amol A Verma
Journal:  CMAJ       Date:  2019-08-06       Impact factor: 8.262

Review 8.  Patent foramen ovale and cryptogenic stroke: diagnosis and updates in secondary stroke prevention.

Authors:  Kristy Yuan; Scott Eric Kasner
Journal:  Stroke Vasc Neurol       Date:  2018-06-26

9.  May-Thurner Syndrome as a Rare Cause of Paradoxical Embolism in a Patient with Patent Foramen Ovale.

Authors:  Dominika M Zoltowska; Guramrinder Thind; Yashwant Agrawal; Vishal Gupta; Jagadeesh Kumar Kalavakunta
Journal:  Case Rep Cardiol       Date:  2018-07-02

10.  A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver.

Authors:  Enfa Zhao; Yajuan Wei; Yafei Zhang; Nina Zhai; Ping Zhao; Baomin Liu
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.