Literature DB >> 24683573

Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up.

Francesco Mangano, Jamil A Shibli, Rachel L Sammons, Giovanni Veronesi, Adriano Piattelli, Carlo Mangano.   

Abstract

PURPOSE: To evaluate the outcome of narrow-diameter (3.3-mm) locking-taper implants used in the rehabilitation of partially and fully edentulous patients over a 10-year period.
MATERIALS AND METHODS: Between January 2002 and December 2011, all patients referred to a private dental clinic for treatment with narrow-diameter implants were enrolled in this study. At each annual follow-up session, clinical and radiographic parameters were assessed; the outcome measurements were implant failure, peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact [DIB]), and biologic and technical complications. The cumulative survival rate (CSR) was assessed using the Kaplan-Meier survival estimator; Tarone-Ware and chi-square analyses were used to evaluate correlations between the study variables. The statistical analysis was performed at the patient- and implant-level.
RESULTS: A total of 324 narrow-diameter implants were placed in 279 patients (159 men, 120 women; age: 25 to 73 years). Four implants failed, for an overall CSR of 98.5% (patient-based) and 98.7% (implant-based) at the 10-year follow-up. The survival rate did not differ significantly with respect to patients' sex, age, smoking or parafunctional habits, bone type, prosthetic restoration, or implant location, position, or length. Among the surviving implants, a mean DIB of 0.31 ± 0.23 mm, 0.45 ± 0.27 mm, and 0.69 ± 0.28 mm was observed at the 1-, 5-, and 10-year follow-up examinations, respectively. A few biologic (1.2%) and technical complications (7.5%) were reported.
CONCLUSIONS: Within the limitations of this study, it can be concluded that narrow-diameter locking-taper implants represent a good treatment option for the prosthetic rehabilitation of partially and totally edentulous patients.

Entities:  

Mesh:

Year:  2014        PMID: 24683573     DOI: 10.11607/jomi.3327

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  The interactions of dendritic cells with osteoblasts on titanium surfaces: an in vitro investigation.

Authors:  Yang Yang; Xuzhu Wang; Richard J Miron; Xiaoxin Zhang
Journal:  Clin Oral Investig       Date:  2019-03-09       Impact factor: 3.573

2.  Custom-Made Computer-Aided-Design/Computer-Aided-Manufacturing Biphasic Calcium-Phosphate Scaffold for Augmentation of an Atrophic Mandibular Anterior Ridge.

Authors:  Francesco Guido Mangano; Piero Antonio Zecca; Ric van Noort; Samvel Apresyan; Giovanna Iezzi; Adriano Piattelli; Aldo Macchi; Carlo Mangano
Journal:  Case Rep Dent       Date:  2015-05-10

3.  Morse Taper Connection Implants Placed in Grafted Sinuses in 65 Patients: A Retrospective Clinical Study with 10 Years of Follow-Up.

Authors:  Francesco Mangano; Renata Bakaj; Irene Frezzato; Alberto Frezzato; Sergio Montini; Carlo Mangano
Journal:  Int J Dent       Date:  2017-08-07

4.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

5.  Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series.

Authors:  Carlo Mangano; Andrea Bianchi; Francesco Guido Mangano; Jessica Dana; Marco Colombo; Ivan Solop; Oleg Admakin
Journal:  3D Print Med       Date:  2020-01-08

6.  Narrow implants (2.75 and 3.25 mm diameter) supporting a fixed splinted prostheses in posterior regions of mandible: one-year results from a prospective cohort study.

Authors:  Tommaso Grandi; Luigi Svezia; Giovanni Grandi
Journal:  Int J Implant Dent       Date:  2017-09-08

7.  Custom-Made Direct Metal Laser Sintering Titanium Subperiosteal Implants: A Retrospective Clinical Study on 70 Patients.

Authors:  Mauro Cerea; Giorgio Andrea Dolcini
Journal:  Biomed Res Int       Date:  2018-05-28       Impact factor: 3.411

8.  Short Narrow Dental Implants versus Long Narrow Dental Implants in Fixed Prostheses: A Prospective Clinical Study.

Authors:  Eduardo Antiua; Virginia Escuer; Mohammad H Alkhraisat
Journal:  Dent J (Basel)       Date:  2022-03-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.