Literature DB >> 24683222

Single-dose bioequivalence assessment of two formulations of polysaccharide iron complex capsules in healthy adult male Chinese volunteers: A sequence-randomized, double-blind, two-way crossover study.

Yuan-Yuan Zhang1, Jun-Hong Liu1, Feng Su1, Ying-Tao Lui1, Jun-Feng Li1.   

Abstract

BACKGROUND: Iron deficiency anemia (IDA) is a common nutritional disease worldwide. Iron supplementation is an efficient method for treating patients with IDA. Polysaccharide iron complex is an oral iron supplement that is associated with generally good tolerability and good bioavailability.
OBJECTIVE: The aim of this study was to evaluate the bioequivalence of 2 branded formulations of polysaccharide iron complex in healthy adult male Chinese volunteers by determining the pharmacokinetic parameters after single-dose oral admi ni strati on.
METHODS: This sequence-randomized, double-blind, 2-way crossover study was carried out in the Affiliated Hospital, Institute of Medical Sciences of Qingdao University, Qingdao, China. Healthy adult male Chinese volunteers were enrolled and evenly randomized to receive 1 of 2 formulations on day 1. Subjects received an oral dose of 150 mg (1 capsule) of polysaccharide iron complex with 150 mL of warm water in the morning. Capsules were of similar size, shape, and color to ensure blinding. Four hours after administration, the subjects were given standardized meals. After a 1-week washout period, the subjects were crossed over to receive the other formulation in a similar manner. The serum iron concentration 12 hours after study drug administration was determined using atomic-absorption spectrometry. The pharmacokinetic parameters Cmax, Tmax, AUC0-t, and AUC0-∞ were obtained and analyzed using the Schuir mann 2 one-sided t test. The 2 formulations were considered bioequi valent if the test/reference ratios of Cmax, AUC0-t, and their 90% CIs were within the range of 70% to 143% for Cmax and within 80% to 125% for AUC0-t. Tolerability was monitored by inquiring whether the subjects had experienced adverse events (AEs), with a focus on gastrointestinal AEs, during the clinic visits during the 24-hour period after drag administration and subsequently via telephone throughout the study.
RESULTS: Thirty adult male Chinese volunteers were assessed for inclusion. Twenty healthy male volunteers (10 in each group) (mean [SD] age, 21.5 [2.9] years [range, 19-23 years]; weight, 66.2 [5-8] kg [range, 56-80 kg]; height, 172.5 [5.1] cm [range, 162-180 cm]) were enrolled and completed the study. The pharmacokinetic parameters of the test and reference formulations were as follows: AUCO-t, 6.58 (2.09) and 6.58 (1.91) μg/mL · h(-1); Cmax, 1.10 (0.28) and 1.07 (0.25) μg/mL; Tmax, 3.93 (0.37) and 3-93 (0.37) hours; t½, 8.33 (0.36) and 8.38 (0.41) hours; and AUC0-∞, 6.93 (2.23) and 6.95 (2.13) μg/mL · h(-1), respectively. There were no statistically significant differences in AUC0-∞ or Tmax by formulation, period, or subject between the test and reference formulations. Similarly, there were no statistically significant differences in Cmax by period; however, a significant difference was found in Cmax by formulation (P = 0.012). No clinically significant AEs were reported with either formulation.
CONCLUSIONS: In these healthy adult male Chinese volunteers, the test formulation of polysaccharide iron complex was found to be bioequivalent to the reference formulation according to the Chinese regulatory definition. A significant difference by formulation was found in Cmax. The sample size was smaller than that recommended by the US Food and Drug Administration for a bioequivalence study, and additional studies with larger sample sizes are needed.

Entities:  

Keywords:  Hongyuanda™; Niferex™; bioequivalence; healthy male volunteers; polysaccharide iron complex

Year:  2009        PMID: 24683222      PMCID: PMC3967362          DOI: 10.1016/j.curtheres.2009.04.006

Source DB:  PubMed          Journal:  Curr Ther Res Clin Exp        ISSN: 0011-393X


  14 in total

1.  On sample size calculation in bioequivalence trials.

Authors:  S C Chow; H Wang
Journal:  J Pharmacokinet Pharmacodyn       Date:  2001-04       Impact factor: 2.745

2.  Iron polysaccharide complex.

Authors:  M U Sanklecha
Journal:  Indian Pediatr       Date:  2002-09       Impact factor: 1.411

3.  Bioequivalence study of two formulations of simvastatin tablets in healthy Thai volunteers.

Authors:  Manupat Lohitnavy; Ornrat Lohitnavy; Kasinee Chaijittiprasert; Prawit Taytiwat; Sanglar Polnok
Journal:  Arzneimittelforschung       Date:  2004

4.  Oral iron therapy with ferrous fumarate and polysaccharide iron complex.

Authors:  E Glassman
Journal:  ANNA J       Date:  1992-06

5.  Oral iron absorption test in patients on CAPD: comparison of ferrous sulfate and a polysaccharide ferric complex.

Authors:  M Tinawi; K J Martin; B Bastani
Journal:  Nephron       Date:  1996       Impact factor: 2.847

6.  [Bioavailability of various iron preparations following oral medication].

Authors:  E Heilmann; G Keim
Journal:  Fortschr Med       Date:  1980-12-18

7.  Iron supplementation in preterm infants: a study comparing the effect and tolerance of a Fe2+ and a nonionic FeIII compound.

Authors:  S Naude; S Clijsen; G Naulaers; H Daniels; C Vanhole; H Devlieger
Journal:  J Clin Pharmacol       Date:  2000-12       Impact factor: 3.126

8.  Comparison of a combination ferrous fumarate product and a polysaccharide iron complex as oral treatments of iron deficiency anemia: a Taiwanese study.

Authors:  Ta-Chih Liu; Shen-Fung Lin; Chao-Sung Chang; Wen-Chi Yang; Tyen-Po Chen
Journal:  Int J Hematol       Date:  2004-12       Impact factor: 2.490

Review 9.  Iron kinetics with emphasis on iron overload.

Authors:  J D Cook; W E Barry; C Hershko; G Fillet; C A Finch
Journal:  Am J Pathol       Date:  1973-08       Impact factor: 4.307

10.  Comparison of polysaccharide iron complexes used as iron supplements.

Authors:  E M Coe; L H Bowen; J A Speer; R D Bereman
Journal:  J Inorg Biochem       Date:  1995-03       Impact factor: 4.155

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.