Vergence facility with stereoscopic and nonstereoscopic targets.

Hamed Momeni-Moghaddam1, David A Goss, Abubakr Dehvari.   

Abstract

PURPOSE: To compare vergence facility with nonstereo and stereo targets in binocular symptomatic and asymptomatic subjects.
METHODS: Sixty-six students were divided into symptomatic and asymptomatic groups according to the Convergence Insufficiency Symptom Survey Questionnaire score. Vergence facility was tested at 40 cm by flipper prism 3Δ BI/12Δ BO (BI, base-in; BO, base-out). The targets used were a nonstereo target (a vertical column of small letter "E" of ~20/30 size), a stereo-local target (fifth set of circles of the Titmus test with stereoacuity of 100 arcsec), and a stereo-global target (page 6 of the TNO test with stereoacuity of 120 arcsec).
RESULTS: Repeated-measures analysis of variance showed differences in the mean vergence facility with different targets in all subjects and separately in two symptom groups (p < 0.001). In all subjects and separately in the symptomatic subjects, this difference was statistically significant among the three different targets (p < 0.05). In the asymptomatic subjects, this difference was not significant between the measured values with nonstereo and stereo-local targets (p > 0.05) but significant for the comparison of stereo-global targets with the other two targets. The receiver operating characteristic curve analysis showed the cutoff points 10.5, 10.5, and 9.75 cycles per minute with nonstereo, stereo-local, and stereo-global targets, respectively. The sensitivity of the three targets used was the same (97%). Specificity was 0.93 or higher with all three targets, with the highest specificity obtained with the stereo-global target (100%).
CONCLUSIONS: The highest vergence facility was obtained with a nonstereo target and the lowest was obtained with a stereo-global target. High sensitivity with all three targets means that there are few false-negative results with them, and the high specificity is indicative of low false-positive results. Hence, the vergence facility predictive value would be high in diagnosing binocular symptomatic patients using a 3Δ BI/12Δ BO prism flipper at near and a response cutoff of about 10 cycles per minute or less.

Entities:  

Mesh:

Year:  2014        PMID: 24681831     DOI: 10.1097/OPX.0000000000000227

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  3 in total

1.  Deterioration of binocular vision after alcohol intake influences driving performance.

Authors:  Francesco Martino; José Juan Castro-Torres; Miriam Casares-López; Sonia Ortiz-Peregrina; Carolina Ortiz; Rosario G Anera
Journal:  Sci Rep       Date:  2021-04-26       Impact factor: 4.379

2.  How to assess visual function in acquired brain injury-Asking is not enough.

Authors:  Märta Berthold-Lindstedt; Jan Johansson; Jan Ygge; Kristian Borg
Journal:  Brain Behav       Date:  2020-11-23       Impact factor: 3.405

3.  Investigation of the Relationship Between Subjective Symptoms of Visual Fatigue and Visual Functions.

Authors:  Fuhao Zheng; Fang Hou; Ruru Chen; Jianhui Mei; Pingping Huang; Bingzhen Chen; Yuwen Wang
Journal:  Front Neurosci       Date:  2021-07-15       Impact factor: 4.677

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.