Literature DB >> 24680450

Fluorescence-enhanced robotic radical cystectomy using unconjugated indocyanine green for pelvic lymphangiography, tumor marking, and mesenteric angiography: the initial clinical experience.

Ted B Manny1, Ashok K Hemal2.   

Abstract

OBJECTIVE: To describe the initial feasibility of fluorescence-enhanced robotic radical cystectomy (FERRC) using real-time cystoscopic injection of unconjugated indocyanine green (ICG) for tumor marking and identification of sentinel lymphatic drainage with additional intravenous injection for mesenteric angiography.
METHODS: Ten patients with clinically localized high-grade bladder cancer underwent FERRC. Before robot docking, rigid cystoscopy was performed, during which a 2.5-mg/mL ICG solution was injected in the bladder submucosa and detrusor circumferentially around the tumor. After robot docking, parameters describing the time course of tissue fluorescence and pelvic lymphangiography were systematically recorded. Lymphatic packets containing fluorescent lymph nodes were considered the sentinel drainage. Eight patients underwent intracorporeal ileal conduit urinary diversion, during which an additional 2-mL ICG solution was given intravenously for mesenteric angiography, allowing maximal preservation of bowel vascularity to the conduit and remaining bowel segments.
RESULTS: Bladder tumor marking and identification of sentinel drainage were achieved in 9 of 10 (90%) patients. The area of bladder tumor was identified at a median of 15 minutes after injection, whereas sentinel drainage was visualized at a median of 30 minutes. Mesenteric angiography was successful in 8 of 8 (100%) patients at a median time of <1 minutes after intravenous injection and enabled identification of bowel arcades before intracorporeal bowel stapling.
CONCLUSION: FERRC using combined cystoscopic and intravenous injection of ICG is safe and feasible. FERRC allows for reliable bladder tumor marking, identification of sentinel lymphatic drainage, and identification of mesenteric vasculature in most patients.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24680450     DOI: 10.1016/j.urology.2013.11.042

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  23 in total

Review 1.  Practical tips for safe and efficient robotic cystectomy.

Authors:  Gregory M Janda; Michael E Woods; Raj S Pruthi
Journal:  Curr Urol Rep       Date:  2015-06       Impact factor: 3.092

2.  Experience of surgeon, hospital, and comprehensive cancer team critical to the outcomes of radical cystectomy and urinary diversion.

Authors:  Ram Anil Pathak; Ashok Kumar Hemal
Journal:  Transl Androl Urol       Date:  2019-07

Review 3.  Advances in fluorescent-image guided surgery.

Authors:  Mark J Landau; Daniel J Gould; Ketan M Patel
Journal:  Ann Transl Med       Date:  2016-10

Review 4.  Sentinel lymph node biopsy in renal malignancy: The past, present and future.

Authors:  Tharani Mahesan; Alberto Coscione; Ben Ayres; Nick Watkin
Journal:  World J Nephrol       Date:  2016-03-06

5.  Best practices in near-infrared fluorescence imaging with indocyanine green (NIRF/ICG)-guided robotic urologic surgery: a systematic review-based expert consensus.

Authors:  Giovanni E Cacciamani; A Shakir; A Tafuri; K Gill; J Han; N Ahmadi; P A Hueber; M Gallucci; G Simone; R Campi; G Vignolini; W C Huang; J Taylor; E Becher; F W B Van Leeuwen; H G Van Der Poel; L P Velet; A K Hemal; A Breda; R Autorino; R Sotelo; M Aron; M M Desai; A L De Castro Abreu
Journal:  World J Urol       Date:  2019-07-08       Impact factor: 4.226

Review 6.  Green indocyanine fluorescence in robotic abdominal surgery.

Authors:  Giuseppe Spinoglio; Emilio Bertani; Simona Borin; Alessandra Piccioli; Wanda Petz
Journal:  Updates Surg       Date:  2018-08-29

Review 7.  Molecular Targeted Fluorescence-Guided Intraoperative Imaging of Bladder Cancer Nodal Drainage Using Indocyanine Green During Radical and Partial Cystectomy.

Authors:  Manish N Patel; Ashok K Hemal
Journal:  Curr Urol Rep       Date:  2016-10       Impact factor: 3.092

Review 8.  A review of performance of near-infrared fluorescence imaging devices used in clinical studies.

Authors:  B Zhu; E M Sevick-Muraca
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

9.  Initial report of near-infrared fluorescence imaging as an intraoperative adjunct for lymph node harvesting during robot-assisted laparoscopic gastrectomy.

Authors:  Gabriel Herrera-Almario; Michael Patane; Inderpal Sarkaria; Vivian E Strong
Journal:  J Surg Oncol       Date:  2016-03-29       Impact factor: 3.454

Review 10.  Robot assisted lymphadenectomy in urology: pelvic, retroperitoneal and inguinal.

Authors:  Giovannalberto Pini; Surena F Matin; Nazareno Suardi; Mihir Desai; Inderbir Gill; James Porter; Robert J Stein; Rene Sotelo; Franco Gaboardi; Francesco Porpiglia
Journal:  Minerva Urol Nefrol       Date:  2016-11-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.