Literature DB >> 24677520

Using a single, high mass resolution mass spectrometry platform to investigate ion suppression effects observed during tissue imaging.

Laura Tomlinson1, Jens Fuchser, Arne Fütterer, Mark Baumert, David G Hassall, Andrew West, Peter S Marshall.   

Abstract

RATIONALE: The signal intensity of a given molecule across a tissue section when measured using mass spectrometry imaging (MSI) is prone to changes caused by the molecular heterogeneity across the surface of the tissue. Here we propose a strategy to investigate these effects using electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) on a single high-resolution mass spectrometry (HRMS) platform.
METHODS: A rat was administered with a single inhaled dose of a compound and sacrificed 1 h after dosing. Sections were prepared from the excised frozen lung and analysed using MALDI, liquid extraction surface analysis (LESA) nano-ESI-MS and nano-ESI liquid chromatography (LC)/MS. The ESI and MALDI ion sources were mounted either side of the ion transfer system of the same Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer.
RESULTS: MALDI MSI clearly demonstrated widespread distribution of the dosed molecule throughout the lung, with the exception of a non-lung section of tissue on the same sample surface. Comparison of the lipid signals across the sample indicated a change in signal between the lung and the adipose tissue present on the same section. Use of ESI and MALDI, with and without an internal standard, supported the evaluation of changes in the signal of the dosed molecule across the tissue section.
CONCLUSIONS: The results demonstrate the successful application of a dual ion source HRMS system to the systematic evaluation of data from MALDI MSI, used to determine the distribution of an inhaled drug in the lung. The system discussed is of great utility in investigating the effects of ion suppression and evaluating the quantitative and qualitative nature of the MSI data.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24677520     DOI: 10.1002/rcm.6869

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  15 in total

1.  Laser Ablation with Vacuum Capture for MALDI Mass Spectrometry of Tissue.

Authors:  Fabrizio Donnarumma; Fan Cao; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2015-09-15       Impact factor: 3.109

2.  Influence of Desorption Conditions on Analyte Sensitivity and Internal Energy in Discrete Tissue or Whole Body Imaging by IR-MALDESI.

Authors:  Elias P Rosen; Mark T Bokhart; H Troy Ghashghaei; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2015-04-04       Impact factor: 3.109

3.  Mass Spectrometry Imaging and GC-MS Profiling of the Mammalian Peripheral Sensory-Motor Circuit.

Authors:  Stanislav S Rubakhin; Alexander Ulanov; Jonathan V Sweedler
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-31       Impact factor: 3.109

4.  Mass spectrometry imaging of levofloxacin distribution in TB-infected pulmonary lesions by MALDI-MSI and continuous liquid microjunction surface sampling.

Authors:  Brendan Prideaux; Mariam S ElNaggar; Matthew Zimmerman; Justin M Wiseman; Xiaohua Li; Véronique Dartois
Journal:  Int J Mass Spectrom       Date:  2015-02-01       Impact factor: 1.986

5.  Profiling of adrenocorticotropic hormone and arginine vasopressin in human pituitary gland and tumor thin tissue sections using droplet-based liquid-microjunction surface-sampling-HPLC-ESI-MS-MS.

Authors:  Vilmos Kertesz; David Calligaris; Daniel R Feldman; Armen Changelian; Edward R Laws; Sandro Santagata; Nathalie Y R Agar; Gary J Van Berkel
Journal:  Anal Bioanal Chem       Date:  2015-06-18       Impact factor: 4.142

6.  Quantitative Mass Spectrometry Imaging with Liquid Microjunction Surface Sampling.

Authors:  Qian Wu; Hongmei Lu
Journal:  Methods Mol Biol       Date:  2022

Review 7.  Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques.

Authors:  Julia Laskin; Ingela Lanekoff
Journal:  Anal Chem       Date:  2015-11-24       Impact factor: 6.986

8.  Small molecule distribution in rat lung: a comparison of various cryoprotectants as inflation media and their applicability to MSI.

Authors:  Sooraj Baijnath; Adeola Shobo; Linda A Bester; Sanil D Singh; Gert Kruger; Tricia Naicker; Thavendran Govender
Journal:  J Mol Histol       Date:  2016-01-13       Impact factor: 2.611

9.  Reduced Hemoglobin Signal and Improved Detection of Endogenous Proteins in Blood-Rich Tissues for MALDI Mass Spectrometry Imaging.

Authors:  Monica Lin; Livia S Eberlin; Erin H Seeley
Journal:  J Am Soc Mass Spectrom       Date:  2022-01-21       Impact factor: 3.262

Review 10.  Mass spectrometry imaging for plant biology: a review.

Authors:  Berin A Boughton; Dinaiz Thinagaran; Daniel Sarabia; Antony Bacic; Ute Roessner
Journal:  Phytochem Rev       Date:  2015-10-13       Impact factor: 5.374

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.