Literature DB >> 24673926

A novel modified dynamic conformal arc technique for treatment of peripheral lung tumors using stereotactic body radiation therapy.

Christopher C Ross1, John J Kim1, Zhe J Chen1, David J Grew2, Bryan W Chang1, Roy H Decker3.   

Abstract

PURPOSE: To describe and compare a novel, modified dynamic conformal arc (MDCA) technique for lung stereotactic body radiation therapy with the standard noncoplanar beam (NCB) technique based on stereotactic body radiation therapy (SBRT) coverage, dose conformality, normal tissue constraints, and treatment time.
MATERIALS AND METHODS: Twenty consecutive medically inoperable patients with early stage, peripheral, non-small cell lung cancer treated with SBRT using an NCB technique were re-planned with a novel MDCA technique. Treatment plans were compared based on Radiation Therapy Oncology Group (RTOG) 0236 criteria for planning treatment volume (PTV) coverage and normal tissue dose constraints, as well as high- and moderate-dose conformality. Treatment times necessary to deliver the NCB plans were compared with the times of a separate group of 12 consecutive patients treated with the MDCA technique at our institution.
RESULTS: The MDCA technique resulted in improved coverage of the cranial and caudal regions of the PTV and generated plans that were significantly more conformal by all high-dose criteria proposed by the RTOG protocol. In terms of moderate-dose criteria, MDCA plans had a significantly lower maximum dose (2 cm from the PTV), whereas the ratio of the 50% dose volume to the volume of the PTV was equivalent between the 2 techniques. All normal tissue dose constraints proposed in the RTOG 0236 protocol were met by each plan, although the median lung V20 and mean lung dose were slightly higher in the MDCA plans, whereas the chest wall dose was slightly lower. A 42% reduction in treatment time was observed when patients treated with the NCB technique were compared with a separate cohort of 12 patients treated with the MDCA technique (P < .0001).
CONCLUSIONS: The new MDCA technique described in this study resulted in enhanced PTV coverage, improved high- and moderate-dose conformality, simplified treatment planning, and reduced treatment time compared with results using the standard NCB technique.
Copyright © 2011 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2011        PMID: 24673926     DOI: 10.1016/j.prro.2010.11.002

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  10 in total

1.  Lung stereotactic body radiotherapy using a coplanar versus a non-coplanar beam technique: a comparison of clinical outcomes.

Authors:  Christopher L Hallemeier; Michael C Stauder; Robert C Miller; Yolanda I Garces; Robert L Foote; Jann N Sarkaria; Heather J Bauer; Charles S Mayo; Kenneth R Olivier
Journal:  J Radiosurg SBRT       Date:  2013

2.  Effects of collimator angle, couch angle, and starting phase on motion-tracking dynamic conformal arc therapy (4D DCAT).

Authors:  Zhengzheng Xu; Rutao Yao; Matthew B Podgorsak; Iris Z Wang
Journal:  J Appl Clin Med Phys       Date:  2017-07-21       Impact factor: 2.102

3.  A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT.

Authors:  Damodar Pokhrel; Justin Visak; Lana Sanford
Journal:  J Appl Clin Med Phys       Date:  2020-04-19       Impact factor: 2.102

4.  New dosimetric guidelines for linear Boltzmann transport equations through comparative evaluation of stereotactic body radiation therapy for lung treatment planning.

Authors:  Matthew Webster; Sean Tanny; Neil Joyce; Amy Herman; Yuhchyau Chen; Michael Milano; Kenneth Usuki; Louis Constine; Deepinder Singh; Inhwan Yeo
Journal:  J Appl Clin Med Phys       Date:  2021-11-16       Impact factor: 2.102

5.  Novel Clinically Weight-Optimized Dynamic Conformal Arcs (WO-DCA) for Liver SBRT: A Comparison with Volumetric Modulated Arc Therapy (VMAT).

Authors:  Yucel Saglam; Yasemin Bolukbasi; Ali Ihsan Atasoy; Fatih Karakose; Mustafa Budak; Vildan Alpan; Erkan Topkan; Ugur Selek
Journal:  Ther Clin Risk Manag       Date:  2021-09-28       Impact factor: 2.423

6.  Improving Delivery Accuracy of Stereotactic Body Radiotherapy to a Moving Tumor Using Simplified Volumetric Modulated Arc Therapy.

Authors:  Young Eun Ko; Byungchul Cho; Su Ssan Kim; Si Yeol Song; Eun Kyung Choi; Seung Do Ahn; Byongyong Yi
Journal:  PLoS One       Date:  2016-06-22       Impact factor: 3.240

7.  A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy.

Authors:  Bradley M Rauschenbach; Luke Mackowiak; Harish K Malhotra
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

8.  Improvement of conformal arc plans by using deformable margin delineation method for stereotactic lung radiotherapy.

Authors:  Görkem Güngör; Melek Demir; Gökhan Aydın; Bülent Yapıcı; Banu Atalar; Enis Özyar
Journal:  J Appl Clin Med Phys       Date:  2017-12-07       Impact factor: 2.102

9.  A simple, yet novel hybrid-dynamic conformal arc therapy planning via flattening filter-free beam for lung stereotactic body radiotherapy.

Authors:  Damodar Pokhrel; Matthew Halfman; Lana Sanford
Journal:  J Appl Clin Med Phys       Date:  2020-04-03       Impact factor: 2.102

10.  Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy.

Authors:  Rasmus Bokrantz; Minna Wedenberg; Peter Sandwall
Journal:  J Appl Clin Med Phys       Date:  2019-12-27       Impact factor: 2.102