Literature DB >> 24673363

Lipid-lipid interactions in aminated reduced graphene oxide interface for biosensing application.

Md Azahar Ali1, K Kamil Reza, Saurabh Srivastava, Ved Varun Agrawal, Renu John, Bansi Dhar Malhotra.   

Abstract

A label-free biosensor based on antiapolipoprotein B 100 functionalized-aminated reduced graphene oxide interface has been fabricated for detection of low density lipoprotein (LDL or lipid) cholesterol. The aminated reduced graphene oxide (NH2-rGO) based electrode surface is covalently functionalized with antiapolipoprotein B 100 (AAB or lipid) using EDC/NHS coupling chemistry. The lipid-lipid interactions at the NH2-rGO electrode surface have been investigated using electrochemical impedance spectroscopic technique. The structural and morphological investigations of NH2-rGO based immunosensor have been accomplished via transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, UV-visible, and electrochemical techniques. The impedimetric response of the proposed immunosensor shows excellent sensitivity (612 Ω mg(-1) dL cm(-2)), a response time of 250 s, and a low detection limit of 5 mg/dL of LDL molecules. The association, dissociation, and equilibrium rate constants for this immunoelectrode are found to be 1.66 M(-1) s(-1), 0.6 s(-1), and 2.77 M(-1), respectively. The long-term stability and excellent reproducibility of the proposed immunosensor indicates a suitable platform for detection of LDL or lipid molecules. This immunosensor provides an efficient platform for analysis of the antigen-antibody interactions of lipid molecules.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24673363     DOI: 10.1021/la4049852

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  4 in total

1.  Detection of Guanine and Adenine Using an Aminated Reduced Graphene Oxide Functional Membrane-Modified Glassy Carbon Electrode.

Authors:  Di Li; Xiao-Lu Yang; Bao-Lin Xiao; Fang-Yong Geng; Jun Hong; Nader Sheibani; Ali Akbar Moosavi-Movahedi
Journal:  Sensors (Basel)       Date:  2017-07-18       Impact factor: 3.576

Review 2.  Application of Functionalized Graphene Oxide Based Biosensors for Health Monitoring: Simple Graphene Derivatives to 3D Printed Platforms.

Authors:  Agnivo Gosai; Kamil Reza Khondakar; Xiao Ma; Md Azahar Ali
Journal:  Biosensors (Basel)       Date:  2021-10-10

3.  Antibody-Ferrocene Conjugates as a Platform for Electro-Chemical Detection of Low-Density Lipoprotein.

Authors:  Daria Rudewicz-Kowalczyk; Iwona Grabowska
Journal:  Molecules       Date:  2022-08-26       Impact factor: 4.927

Review 4.  Detection of Lipid and Amphiphilic Biomarkers for Disease Diagnostics.

Authors:  Jessica Z Kubicek-Sutherland; Dung M Vu; Heather M Mendez; Shailja Jakhar; Harshini Mukundan
Journal:  Biosensors (Basel)       Date:  2017-07-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.